Disinfecting RO Membranes - Procuedure

Membrane Chemicals Product Support


To Disinfect RO Membranes:

  1. Clean the membrane with AM-22 or AM-23*.  AM-22 or AM-23* will remove deposits in the membrane which harbor microorganisms.  After cleaning, flush the membrane with RO permeate.

  2. Clean the membrane with AM-124 to remove iron and other transition metals.  After cleaning,  flush the membrane with RO permeate.

  3. Circulate a solution of PS-77* through the membrane in a ratio of 1:100 with RO permeate for 30 minutes, at a temperature not to exceed 77°F.

  4. Allow the membrane to soak in the disinfecting solution for 30 minutes.  After disinfecting, flush the membrane with RO permeate.

    * Items with an asterisk are classified as hazardous materials and are not available for shipment by UPS or air.  Available for common carrier or ocean shipment only.

    Caution:  PS-77
    * is not recommended in contact with brass, copper, or iron parts and fittings of an RO System.  Handle all chemicals with care.  Wear protective clothing and eye protection.

disin.gif (71334 bytes)

 


 

For prompt, courteous and reliable service, contact us today!


Home Products Catalog How To Order Company Info Contact Us Download Forms Technical Site Search Overstock Sale Employment Order Online
Back Up
Cleaning Systems Membrane Chemicals Cleaning Cartridges Flocon Antiscalant Chemical Info Downloads Preserving Cartridges Using Flocon Flocon Dosage Calculations Flocon 260 Effectiveness - UCLA Study Overview.pdf When to Clean Membranes Foulant Symptoms Cleaner Selection Cleaning Flow Rates Cleaning Procedures AM-88 Preservative Disinfectant Procedures

Copyright © 2010 Applied Membranes, Inc. All Rights Reserved.

 

 

[Contact Us] [How to Purchase our Products] [Download Catalog] [Download Manuals] [Download Forms & Product Literature] [Track an Order] [Membranes] [RO Systems] [Seawater Desalination Systems] [Water Treatment Systems] [Media Filtration] [Water Softeners] [Iron Filters] [Filters & Housings] [Membrane Housings/Pressure Vessels] [Residential Components] [Pumps] [Membrane Chemicals] [Ultraviolet] [Water Quality Test Equipment] [About Applied Membranes]