Industry Leader in RO Expertise and Membrane Applications Since 1983™
Our Products Company Info Product Catalog Technical Site Contact Us Search

Membrane Chemicals

Disinfecting Procedure for Membranes

  1. Clean the membrane with AM-22 or AM-23*.  AM-22 or AM-23* will remove deposits in the membrane which harbor microorganisms.  After cleaning, flush the membrane with RO permeate.

  2. Clean the membrane with AM-124 to remove iron and other transition metals.  After cleaning,  flush the membrane with RO permeate.

  3. Circulate a solution of PS-77* through the membrane in a ratio of 1:100 with RO permeate for 30 minutes, at a temperature not to exceed 77°F.

  4. Allow the membrane to soak in the disinfecting solution for 30 minutes.  After disinfecting, flush the membrane with RO permeate.

    * Items with an asterisk are classified as hazardous materials and are not available for shipment by UPS or air.  Available for common carrier or ocean shipment only.

    Caution:  PS-77
    * is not recommended in contact with brass, copper, or iron parts and fittings of an RO System.  Handle all chemicals with care.  Wear protective clothing and eye protection.