AMI
Supplies Two Reverse Osmosis Systems to Pepsi Cola
AMI Commissioned two Reverse Osmosis Systems in a Pepsi Cola
Plant. The combined systems produce in excess of half a million
gallons per day of product water. The Systems are skid-mounted
and use Grundfos Pumps and FilmTec Membranes.
 |
|
Automated
Shipping System Offers Benefits to Our Customers
Our automated shipping system has been running
smoothly for over a year. This system allows customers to track
the status of their shipment on our website using their own
purchase order number. In addition, an e-mail containing the
tracking information and shipment details is automatically sent to
the customer at the end of the day.
All Stock Orders Received by 3:00 PM will Ship the Same Day!
|
Featured Product:
Affordable SDI
|
The most affordable and complete
SDI Kits on the market are available from Applied Membranes,
Inc. These include ASTM Instructions to determine Silt
Density Index. The kit offers portability for onsite
measurement. |
 |
|
Model # |
Description |
Lead Time |
| Y-SDIKIT |
Complete Silt Density Index Measurement Kit |
2-4 Weeks |
|
|
Would
you like to receive this monthly
newsletter every month by e-mail?
If so, please provide us with your e-mail address below! |
|
|
Technical Note By Dr. Dhawan:
Biological
Growth on Membranes: Storage, Shipping, and System Shut-Down
Membrane Storage:
Store Membranes in
a cool area out of direct sunlight. Membrane storage temperature
limits are 22°F-113°F. Dry (new) elements can go below 22°F.
Preserve in a
solution of 2% AM-88 and 20% AM-16. This will not prevent freezing
below 32°F, but the crystals are soft and the membrane is not
damaged.
Keep new elements
in their original packaging.
Examine the
preservative in preserved elements every 3 months. If not clear,
remove and re-preserve. The pH of the preservative should not drop
below 3.
Storage time of
dry elements is unlimited.
Membrane Shipping:
Preserve the
element in the plastic bag using the recommended procedure. Make
sure the plastic bag does not leak and the element is properly
identified.
Make sure the
preservative solution is correctly labeled.
Protect the
element package from physical damage.
System Shut-Down:
Clean the
membranes in the system using the cleaning procedure.
Circulate the
preservative solution.
Shut down the
system and close valves to avoid air entering the system.
Check preservative
once a month.
|
|