Industry Leader in RO Expertise and Membrane Applications Since 1983™
Our Products Company Info Catalog Technical Site Contact Us Search How To Order

Extra-Low Energy Tap Water Thin Film Elements
 
Extra-Low Energy Elements in all sizes are now available from AMI.  These membranes are specially designed to produce the same product flow rate as the earlier models, but at a lower pressure.  By using these instead of standard elements, you can significantly reduce your operating costs.

Model Permeate Flow Rate Size
(Dia." × Length")
PSI Minimum Salt Rejection (%) Stabilized Salt Rejection (%) Specification_Sheets
Gal/Day Liters/Day

M-T2026AXLE

240

908 2.0 × 26 100

98

99

M-T2514AXLE

190

719 2.5 × 14 100

98

99

M-T2521AXLE

365

1382 2.5 × 21 100

98

99

M-T2540AXLE

850

3217 2.5 × 40 100

98

99

M-T4014AXLE

540

2044 4.0 × 14 100

98

99

M-T4021AXLE

1025

3880 4.0 × 21 100

98

99

M-T4040AXLE

2860

10,825 4.0 × 40 100

98

99
Note:  Performance specifications based on, 2000 mg/l sodium chloride, 100 psi applied pressure,  77°F (25°C) feed  water temperature,  pH 8 and 10% recovery.  Element permeate flow may vary -15%/+25%.  Low energy membranes in all sizes are now available from AMI.  These membranes produce similar product flow as the earlier models but at a lower pressure.  A word of caution:  Do not run these membranes at a pressure that will produce more than their rated product  flow rate.  This will lead to premature  fouling of the membrane resulting in drop in permeate flow and higher TDS of the permeate.E


Actual sizes pictured below

DIMENSIONS

Model No.
L
Inches Cm
I
Inches Cm
D
Inches Cm
M-T2026AXLE 26 66.0 23.64 60 1.8 4.6
M-T2514AXLE 14 35.6 12 30 2.5 6.4
M-T2521AXLE 21 53.3 19 48 2.5 6.4
M-T2540AXLE 40 101.6 38 96 2.5 6.4
M-T4014AXLE 14 35.6 12 30 3.9 9.9
M-T4021AXLE 21 53.3 19 48 3.9 9.9
M-T4040AXLE 40 101.6 38 96 3.9 9.9

RECOMMENDED OPERATION CONDITIONS

  • Maximum Applied Pressure
300 psi (2.1 MPa)
  • Maximum Feed Flow Rate - 
    • 2" elements:
    • 2.5" elements:
    • 4" elements:

3 gpm
6 gpm
17 gpm
  • Maximum Operating Temperature
113° F (45° C)
  • Maximum Feed Water Turbidity
1 NTU
  • Maximum Feed Water SDI (15min)
4
  • Chlorine Tolerance
0
  • Feedwater pH Range, continuous operation
2-11
  • Feedwater pH Range, short-term cleaning (30 min)
1-12
  • Single Element recovery %
15

 

MEMBRANE PHOTOS

M-T2026AXLE

M-T2514AXLE

M-T2521AXLE

M-T2540AXLE

M-T4014AXLE

M-T4021AXLE

M-T4040AXLE

This page was last updated 08/21/06

 


 