Extra-Low Energy (XLE) Reverse Osmosis Membranes

Extra-Low Energy RO Membranes in all sizes are now available from AMI.  These XLE membranes are specially designed to produce the same product flow rate as the earlier models, but at a lower pressure.  By using these instead of standard RO Membrane Elements, you can significantly reduce your operating costs.

Membrane Model Permeate Flow Rate Size
(Dia." × Length")
PSI Minimum Salt Rejection (%) Stabilized Salt Rejection (%) Specification Sheets
Gal/Day Liters/Day

M-T2026AXLE

240

908 2.0 × 26 100

98

99 specs for 2' XLE RO Membranes

M-T2514AXLE

190

719 2.5 × 14 100

98

99 Specs for 2.5' XLE RO Membranes

M-T2521AXLE

365

1382 2.5 × 21 100

98

99

M-T2540AXLE

850

3217 2.5 × 40 100

98

99

M-T4014AXLE

540

2044 4.0 × 14 100

98

99 Specs for 4' XLE Reverse Osmosis Membranes

M-T4021AXLE

1025

3880 4.0 × 21 100

98

99

M-T4040AXLE

2860

10,825 4.0 × 40 100

98

99
Note:  Performance specifications based on, 2000 mg/l sodium chloride, 100 psi applied pressure,  77°F (25°C) feed  water temperature,  pH 8 and 10% recovery.  Element permeate flow may vary -15%/+25%.  Low energy membranes in all sizes are now available from AMI.  These membranes produce similar product flow as the earlier models but at a lower pressure.  A word of caution:  Do not run these membranes at a pressure that will produce more than their rated product  flow rate.  This will lead to premature  fouling of the membrane resulting in drop in permeate flow and higher TDS of the permeate.E

XLE Reverse Osmosis Membrane
Actual sizes pictured below

RO MEMBRANE DIMENSIONS

Model No.
L
Inches Cm
I
Inches Cm
D
Inches Cm
M-T2026AXLE 26 66.0 23.64 60 1.8 4.6
M-T2514AXLE 14 35.6 12 30 2.5 6.4
M-T2521AXLE 21 53.3 19 48 2.5 6.4
M-T2540AXLE 40 101.6 38 96 2.5 6.4
M-T4014AXLE 14 35.6 12 30 3.9 9.9
M-T4021AXLE 21 53.3 19 48 3.9 9.9
M-T4040AXLE 40 101.6 38 96 3.9 9.9

RECOMMENDED OPERATION CONDITIONS

  • Maximum Applied Pressure
300 psi (2.1 MPa)
  • Maximum Feed Flow Rate - 
    • 2" elements:
    • 2.5" elements:
    • 4" elements:

3 gpm
6 gpm
17 gpm
  • Maximum Operating Temperature
113° F (45° C)
  • Maximum Feed Water Turbidity
1 NTU
  • Maximum Feed Water SDI (15min)
4
  • Chlorine Tolerance
0
  • Feedwater pH Range, continuous operation
2-11
  • Feedwater pH Range, short-term cleaning (30 min)
1-12
  • Single Element recovery %
15

 

MEMBRANE PHOTOS

M-T2026AXLE

M-T2514AXLE

M-T2521AXLE

M-T2540AXLE

M-T4014AXLE

M-T4021AXLE

M-T4040AXLE

 

Top of page

For prompt, courteous and reliable service, contact us today!



Products | Overstock Sale | How to Order | About Us | Contact Us | Support & Downloads | Technical Site | Employment | Search
Reverse Osmosis Systems (RO Systems) | Water Treatment Systems | Membrane Elements | Reverse Osmosis Membranes ( RO Membranes) | Ultrafiltration Membranes ( UF Membranes) | Membrane Housings (Pressure Vessels) | Water Softeners | Media Filters| Water Filters | Home RO Accessories | Water Treatment Insturments | RO Pumps | Membrane Chemicals | Ultraviolet Water Systems (UV Systems) | Water Testers