Complete Reverse Osmosis RO Systems
Series L Reverse
Osmosis
Reverse Osmosis Systems
300 to
19,000 Gallons/Day
For feed water TDS 500 to 1000 PPM
Designed to produce low dissolved solids water from tap or well water, these
RO systems use high efficiency reverse osmosis membranes. The product water
is used in applications such as spot free rinse, water stores, whole house,
labs, ice makers, humidification, misting and a wide variety of other
applications.
Part of the L-series family (other systems include XL and HL series), these
RO systems are designed to work at pressures of 200-250 psi for higher TDS
water and use TW reverse osmosis membranes. The TW RO membranes offer higher
salt removal and the higher operating pressure overcomes the loss of
membrane flow due to higher TDS level.
These reverse osmosis systems use the proven, reliable components and are
mounted on a sturdy powder-coated metal frame. There are numerous design
details learned from years of experience that are incorporated in our water
filtration systems. Our process and fluid design ensures an optimum membrane
life and minimizes the membrane fouling.
Key Features:
-
Over 25 years
of experience is reflected in our quality
-
Compact,
Heavy Duty, Powder Coated Frame
-
Proven
components used throughout the system
-
Conservatively engineered for reliable long term performance
-
Factory
tested to ensure trouble-free operation
Why Applied
Membranes?
-
Over 10,000
commercial/industrial systems in operation
-
Our products
are being used in over 100 countries worldwide
-
From packaged
systems to custom engineered Reverse Osmosis systems, we can take care
of your needs
-
We are one of
the few companies that have the expertise to provide Reverse Osmosis
systems for drinking water, boiler feed water, seawater, desalination,
ultrapure water, USP water, and water reuse.
-
We have
supplied more systems to more countries than most of our competitors
-
Our customers
include major national and international companies in every field of
application
-
We stock more
components for all sizes of RO systems than any other company
-
We have
earned an enviable reputation for our product quality, performance
reliability and business integrity.
STANDARD
EQUIPMENT
- Thin Film Composite Membranes
- Stainless steel membrane pressure
vessels
- 5 micron 20” cartridge filter &
housing
- Feed water temperature gauge
- Automatic inlet feed solenoid valve
- Permeate flowmeter
- Concentrate flowmeter
- Recycle flowmeter
- System control valve
- Recycle control valve
- Low pressure pump protection
- High pressure RO pump
-
- Rotary Vane brass for L-12521 –
L-24A
- Stainless steel multistage for
L-34A – L-124A with SS pump throttling valve
- Automatic membrane flush
- 4) Liquid filled pressure gauges for
filter in/out and system pressures
- Product TDS displayed on controller
LED
- System on/off with 2-level tank
floats
- Powder coated carbon steel frame
- Boxed and palletized for shipment
|

Standard L Frame: Up to L-64A

Expanded L Frame: L-74A and Up |
| |
|
MICROPROCESSOR CONTROLLER FOR
AUTOMATIC OPERATION |
|
Monitors and/or Controls:
-
Inlet valve
-
Delayed start-up of high pressure pump
-
Feed water flush at system shut-down
-
Low pressure switch
-
On/Off with tank level
-
Permeate Quality (TDS )
-
Pre-treatment backwash/lockout
Features:
-
Backlit LED Display
-
LED indicator light for system
status/alarm
-
Front panel access port for
calibration of TDS sensor
-
LED indicator light for water quality
(TDS)
-
Start-up and shut-down with tank
level
-
Feed flush at shut-down
-
Low pressure shut-down
-
Low pressure automatic restart
-
Delayed start-up of high pressure
pump
|
UL508A Labeled

Controller Model S100
LED Display:
-
Permeate Quality (TDS)
-
Operating Status
-
Alarm Condition
|
|
Recommended Optional Equipment (not included)
|
RO System
Specifications
|
Model |
Flow Capacity |
Membrane Elements |
Line Size (in/cm) |
System Dimensions
(in/cm) |
Approx. Shipping
Weight (lb/kg) |
|
Gallons/Day |
m³/day |
Qty. |
Diameter (in/cm) |
Length (in/cm) |
Inlet |
Permeate |
Concentrate |
Length |
Depth |
Height |
| L-12521A-116 |
300 |
1 |
1 |
2.5/6 |
21/53 |
0.75/2 |
0.38/1 |
0.38/1 |
20/51 |
24/61 |
55/140 |
230/104 |
| L-125A-116 |
600 |
2 |
1 |
2.5/6 |
40/102 |
0.75/2 |
0.38/1 |
0.38/1 |
20/51 |
24/61 |
55/140 |
240/109 |
| L-225A-116 |
1,200 |
5 |
2 |
2.5/6 |
40/102 |
0.75/2 |
0.38/1 |
0.38/1 |
20/51 |
24/61 |
55/140 |
250/113 |
| L-14A-116 |
1,800 |
7 |
1 |
4/10 |
40/102 |
0.75/2 |
0.5/1.3 |
0.5/1.3 |
20/51 |
24/61 |
55/140 |
275/125 |
| L-24A-116 |
3,000 |
12 |
2 |
4/10 |
40/102 |
0.75/2 |
0.5/1.3 |
0.5/1.3 |
20/51 |
24/61 |
55/140 |
300/136 |
| L-34A-216 |
5,500 |
21 |
3 |
4/10 |
40/102 |
0.75/2 |
0.5/1.3 |
0.5/1.3 |
20/51 |
32/82 |
55/140 |
325/147 |
| L-44A-216 |
7,000 |
27 |
4 |
4/10 |
40/102 |
0.75/2 |
0.5/1.3 |
0.5/1.3 |
20/51 |
32/82 |
55/140 |
350/159 |
| L-54A-216 |
8,500 |
32 |
5 |
4/10 |
40/102 |
0.75/2 |
0.5/1.3 |
0.5/1.3 |
20/51 |
32/82 |
55/140 |
375/170 |
| L-64A-216 |
10,000 |
38 |
6 |
4/10 |
40/102 |
0.75/2 |
0.5/1.3 |
0.5/1.3 |
20/51 |
32/82 |
55/140 |
400/181 |
| L-74A-216 |
11,500 |
44 |
7 |
4/10 |
40/102 |
0.75/2 |
0.5/1.3 |
0.5/1.3 |
20/51 |
40/102 |
55/140 |
441/200 |
| L-84A-216 |
13,000 |
49 |
8 |
4/10 |
40/102 |
0.75/2 |
0.5/1.3 |
0.5/1.3 |
20/51 |
40/102 |
55/140 |
466/211 |
| L-94A-216 |
14,400 |
55 |
9 |
4/10 |
40/102 |
0.75/2 |
0.5/1.3 |
0.5/1.3 |
20/51 |
40/102 |
55/140 |
491/223 |
| L-104A-216 |
16,000 |
60 |
10 |
4/10 |
40/102 |
0.75/2 |
0.5/1.3 |
0.5/1.3 |
20/51 |
46/117 |
55/140 |
516/234 |
| L-114A-216 |
17,300 |
66 |
11 |
4/10 |
40/102 |
0.75/2 |
0.5/1.3 |
0.5/1.3 |
20/51 |
46/117 |
55/140 |
541/245 |
| L-124A-216 |
19,000 |
72 |
12 |
4/10 |
40/102 |
0.75/2 |
0.5/1.3 |
0.5/1.3 |
20/51 |
46/117 |
55/140 |
566/257 |
Options and
Accessories Available (order separately)
AMI's L Series RO Systems are available with a
wide variety of optional add-on equipment. All assemblies include hardware
and mounting equipment for easy upgrade to your new or existing system
installation.
Expansion Kits to Meet your Future Water Requirements!
Will your water requirements change in
the future? L Series systems are expandable to allow for quick, easy
and cost effective upgrades to systems in the field. Simply purchase and
install the appropriate expansion kit assembly to increase your system
capacity at any time down the road.
-
Single Expansion Package
- with 1) 4" x 40" Membrane & Vessel Kit
Part #: A627
To add a single 4"x40"
RO Membrane to any L Series System. Expansion from 6 to 7
membranes requires an extension bracket (below).
-
Extension Bracket for L Series System
Part #: A628
To accommodate up to 12 RO
Membranes. Required when updating from 6 or less to 7 or more
membranes.
|
Click
any photo below to Enlarge |
|
|
Wall Mount Filter Cartridges
Includes mounting bracket and Isolation
Valves to close the line when changing the filter cartridge.
Part # A711
Filter cartridge must be ordered
separately - common options are shown below. Any 20" Big Blue size
cartridge can be installed.
Click here
to view our complete filter cartridge product selection.
| Pretreatment
Options Available: |
- Sediment Filters in a
variety of micron ratings -
- Scale Inhibitor
Cartridges - Filter Model H-F4220SOFT.
Click for Product Details
- Block Carbon Filter
Cartridges
Block Carbon filter
cartridges produce no carbon fines.
|
| Post-treatment
Options Available: |
|
|
|

 |
Softeners & Media Filtration Pre/Post Treatment
AMI Media filters feature fully automatic
backwash or regeneration for easy, trouble free maintenance.
Ensure superior system operation and extended membrane life by providing
proper pretreatment to the incoming feed water on a continuous basis.
Common pretreatment or post-treatment methods include:
-
Single or Twin Water Softener to
remove hardness and scale.
-
Multi-Media Filter for sediment
filtration to approximately 10 microns.
-
Carbon Filter to remove chlorine.
-
Calcite Filter to neutralize the pH of the RO product water.
Click Here to visit the Media Filtration section
of our site for detailed information on the full line of media filtration
products we carry. |
 |
Chemical Injection System
Antiscalant injection as an alternative to a water softener for scale
control, or
Sodium Metabisulfite injection as an
alternative to a carbon filter to remove chlorine.
|
 |
Water Quality Monitors
Pre-packaged wall-mountable water quality
monitoring controls allow you to monitor the quality of the incoming
feed or RO product water. Assembly includes the monitor, enclosure
and sensor.
| Available Options
for Monitoring Incoming Feed Water Quality: |
- ORP -
60Hz Part #
A246, 50Hz Part # A247
- pH -
60Hz Part #
A244, 50Hz Part # A245
|
| Available Options
for Monitoring RO Product Water Quality: |
- Total Dissolved Solids
(TDS) -
60Hz Part # A242, 50Hz Part # A243
- Resistivity -
60Hz Part #
A248, 50Hz Part # A249
- pH -
60Hz Part # A244, 50Hz Part # A245
|
|
 |
Ultraviolet (UV) Systems
Add an ultraviolet water sterilizer for a 99.9% reduction of bacteria
and viruses in the feed and/or permeate line.
Note: For feed line, wall-mount filter cartridge assembly shown
above is required.
|
 |
Tank Pressure Controls
To automatically turn the RO system on or off with the permeate storage
tank level. For use with a pressurized storage tank (sold
separately).
-
110v/60Hz - Part # A620
-
220v/60Hz - Part # A621
|
 |
Pressurized Storage Tank
Pressurized permeate storage tank available in 40 or 80 gallon volume.
Assembly includes tank, valve, piping, tubing, and pressure gauge.
|
 |
Tank Level Controls
Turns system on or off according to the water level in an atmospheric
storage tank.
Atmospheric storage tank and
repressurization pump are sold separately. |
 |
Atmospheric Storage Tank
Atmospheric Permeate Storage tank.
Assembly includes bulkheads and vent filter. For use with Tank
Level Controls (sold separately).
|
 |
Delivery System
20 GPM, 50 PSI, 220v/1ph/50-60Hz
Includes Pump, 40 Gallon Pressure Tank,
Controls and Fittings
Part # A606-216 |
|
Prefilter Pressure Gauge
To allow for monitoring of the in and out pressure of the prefilter in
order to indicate when the cartridge needs to be changed. Assembly
includes pressure gauge and fittings.
Part # A623 |
 |
Floor Casters Kit
2 Locking casters and 2 Swivel casters to
mount at the base of the stand for ease of system mobility.
Part #: A625 |
 |
|
Notes: |
- All dimensions and weights are
approximate.
- Capacity Basis: 24 hrs/day
- Systems rated at: 77°F (25°C) using 1000
ppm sodium chloride solution operating at approx. 200 psi (14
kg/cm²) pressure. For feed water with higher TDS refer to our Series
HL brochure.
- Minimum feed
pressure to RO System: 40-60 PSI. System capacity changes
significantly with water temperature
- Chlorine must be removed if present in
feed water prior to RO with a carbon filter.
- Pretreatment for water hardness using a
softener should be added to avoid scaling the membranes.
- Feed water turbidity: Less than 1 NTU;
Feed water silt density index (SDI): 3 maximum. If exceeded,
pretreatment with media filter recommended. All pretreatment
equipment and SDI test kits are available from Applied Membranes.
|
|
Voltage: |
Above models indicate recommended voltage codes
per model. Alternative voltages can be ordered using
the voltage codes from the table below.
Available Voltages:
|
Voltage |
L-12521A |
L-125A |
L-225A |
L-14A |
L-24A |
L-34A |
L-44A |
L-54A |
L-64A |
L-74A |
L-84A |
L-94A |
L-104A |
L-114A |
L-124A |
|
-116 = 120V/1Ph/60Hz |
ü |
ü |
ü |
ü |
ü |
-- |
-- |
-- |
-- |
-- |
-- |
-- |
-- |
-- |
-- |
|
-216 = 220-240V/1Ph/60Hz |
ü |
ü |
ü |
ü |
ü |
ü |
ü |
ü |
ü |
ü |
ü |
ü |
ü |
ü |
ü |
|
-215 = 220-240V/1Ph/50Hz |
ü |
ü |
ü |
ü |
ü |
ü |
ü |
ü |
ü |
ü |
ü |
ü |
ü |
ü |
ü |
|
-236 = 240V/3Ph/60Hz |
-- |
-- |
-- |
-- |
-- |
ü |
ü |
ü |
ü |
ü |
ü |
ü |
ü |
ü |
ü |
|
-235 = 240V/3Ph/50Hz |
-- |
-- |
-- |
-- |
-- |
ü |
ü |
ü |
ü |
ü |
ü |
ü |
ü |
ü |
ü |
|
-436 = 460V/3Ph/60Hz |
-- |
-- |
-- |
-- |
-- |
ü |
ü |
ü |
ü |
ü |
ü |
ü |
ü |
ü |
ü |
|
| Replacement