Industry Leader in RO Expertise and Membrane Applications Since 1983™
Our Products Company Info Catalog Technical Site Contact Us Search How To Order



       

Nanofiltration Membranes:  NF5 Elements


NF Membrane Model No. Permeate Flow Rate Size
(Dia" × Length")
Average Salt Rejection (%) Average Hardness Rejection (%) Specification Sheets
Gals/Day Liters/Day
M-N1812A5 36 136 1.8 × 12 50 97+
M-N2514A5 175 662 2.5 × 14 50 97+
M-N2521A5 250 668 2.5 × 21 50 97+
M-N2540A5 600 1602 2.5 × 40 50 97+
M-N4014A5 450 1203 4.0 × 14 50 97+
M-N4021A5 800 3028 4.0 × 21 50 97+
M-N4040A5 2000 7570 4.0 × 40 50 97+
M-N4040A5-D* 2000 7570 4.0 × 40 50 97+

*M-N4004A5-D is Flush Style.  Replaces Desal 5.

Note:  Performance specifications based on 2,000 mg/l sodium chloride, 150 psi (1MPa) applied pressure, 77°F (25°C) feed water temperature, pH 8 and 10% recovery.  Element permeate flow may vary ± 15%.

DIMENSIONS OF NF MEMBRANES

Model No.
L
Inches Cm
I
Inches Cm
D
Inches Cm
M-N1812A5 11.63 29.5 10.0 25.4 1.8 4.6
M-N2514A5 14 35.6 12 30 2.5 6.4
M-N2521A5 21 53.3 19 48 2.5 6.4
M-N2540A5 40 101.6 38 96 2.5 6.4
M-N4014A5 14 35.6 12 30 3.9 9.9
M-N4021A5 21 53.3 19 48 3.9 9.9
M-N4040A5 40 101.6 38 96 3.9 9.9
M-N4040A5-D 40 101.6 -- -- 3.9 9.9

 

RECOMMENDED OPERATION CONDITIONS FOR NANOFILTRATION MEMBRANES

  • Maximum operating pressure
300 psi
  • Maximum feed flow rate - 
    • 2.5" Elements
    • 4" Elements

6 gpm
17 gpm
  • Maximum operating temperature
113° F (45° C)
  • Maximum feed water turbidity
1 NTU
  • Maximum feed water SDI (15min)
4
  • Chlorine tolerance
Up to 1 ppm
  • Feedwater pH range, continuous operation
4-11

This page was last updated 10/30/06


 