VIQUA Sterilight Platinum Series Ultraviolet (UV) Systems
The VIQUA (R-Can) Sterilight Platinum Ultraviolet system is designed to optimize the fluid flow path and ensure the ultraviolet light is efficiently and uniformly delivered to any microbiological organism residing in the water. The Platinum reactor's unique flow distributor ensures that the water follows the most optimum path in its region, eliminating the short circuit flow path created by uneven flow within the reactor.
 |
System Tested and Certified by NSF International against NSF Standard 55 for Disinfection Performance, Class A
Models: SPV-1.5, SPV-2.5, SPV-3.5, SPV-6, SPV-8, SPV-12, SPV-15, SPV-20 |
|
 |
|
Features of the Sterilight Platinum Ice Controller
- 90-265 VAC universal operation
- Visual UV intensity reading (reads in % UV output)
- Visual elapsed time meter - displays remaining lamp life and total controller running time.
- Constant current output over entire line voltage
- Active power factor correction
- EMI/RFI filtering (meets new CE directives)
- One controller to drive all lamps
- Isolated power source for alarm system
- True lamp current detection
- Full diagnostic check on start-up
- Separate fuse protection for controller circuit.
- Dry contacts (for solenoid, lamps, audible alarms, etc.)
- RJ-11 communication port (sensor output & future RG remote alarm package)
- Universal IEC power input connector
Additional Features of Sterilight Platinum Series
- Safety-Loc™ Connector - Interlock switch molded into the lamp connector, preventing lamp operation when the lamp is not fully inserted into the reactor chamber. This connector is keyed to the reactor chamber, allowing for the correct lamp orientation within the reactor, eliminating potentially false sensor readings.
- Flow-Pace™ UV Sensor - 254nm sensor capable of detecting a low-flow condition and automatically adjust the lamp power to the water flow, resulting in lower power consumption, reduced operational costs & less heat transfer into the water.
- Sterilume™ Lamps - Sterilight's low pressure high output lamp offering consistent UV output over the life of the lamp.
|
|
| |
 |
|
Flow Distributor
Above image shows water track path lines as they go through the flow distributor |
|
|
 |
|
Flow Distributor Comparison
Above image shows water track lines with no flow distributor |
|
|
|
| |
 |
|
Platinum System
|
|
|
 |
|
Platinum Ice Controller
|
|
|
|
| |
 |
|
Flow-Pace™ UV Sensor |
|
|
 |
|
Safety-Loc™ Connector |
|
|
|
|
Sterilight Platinum Series UV Systems - NSF Certified - 316 SS
Please note that this product line has recently changed. The newest information is in this table. The cross reference information and specifications for the old part #'s. are listed at the bottom of this page. Click here to skip to that section.
| New Model # |
Replaces Model # |
Flow Rate* |
Lamp Watts |
Inlet/Outlet Connection, MNPT (In.) |
Dimensions, Inches |
Weight Lbs. |
| GPM |
L/Min |
Chamber (L"xD") |
Controller (L"xW"xH") |
| SPV-200 |
SPV-2.5 |
2.6 |
9.8 |
30 |
1/2 |
15.8×3.5 |
10.75×4.5×2 |
12 |
| SPV-410 |
SPV-6 |
6.0 |
22.7 |
36 |
3/4F, 1M |
22.8×3.5 |
10.75×4.5×2 |
16 |
| SPV-600 |
SPV-8 |
8.0 |
30.3 |
45 |
3/4F,1M |
26.0×3.5 |
10.75×4.5×2 |
18 |
| SPV-740 |
SPV-12 |
12.0 |
45.4 |
65 |
3/4F,1M |
30.7×3.5 |
10.75×4.5×2 |
20 |
| SPV-950 |
SPV-15 |
15.0 |
56.8 |
80 |
3/4F,1M |
39.4×3.5 |
10.75×4.5×2 |
25 |
Models listed above are 90-265v-50-60Hz w/Std North American 3 Prong Grounded Power Cord. For other power cord type, use appropriate suffix below:
Continental European 2-pin power = /2, • UK 3 Prong Grounded = /2B, • Australian 3 Prong Grounded = /2A • No Connector "Bare Leads" = NC, Example: SPV-1.5/2B = British Power Cord.
*Flow rates stated as determined by NSF Standard 55 testing. (40 mJ/cm² @ UVT>75% @ fall-safe point).
Please note that the NSF/ANSI Certified systems above contain a flow restrictor to limit the flow at the certified level.
Sterilight Platinum Series UV Systems - Non NSF Certified - 304 SS
Model # |
Flow Rate * |
Lamp Watts |
Inlet/Outlet Connection MNPT (In.) |
Dimensions, Inches |
Weight Lbs. |
| @ 16 mJ/cm² |
@ 40 mJ/cm² |
Chamber (L" x D") |
Controller (L"xW"xH") |
| GPM |
L/Min |
GPM |
L/Min |
| SP100-HO |
11 |
41.6 |
4 |
15.1 |
15 |
3/4F, 1"M |
13.8×3.5 |
10.75×4.5×2 |
10 |
| SP150-HO |
14 |
53.0 |
6 |
22.7 |
20 |
3/4F, 1"M |
15.8×3.5 |
10.75×4.5×2 |
11 |
| SP200-HO |
20 |
75.7 |
8 |
30.3 |
30 |
3/4F, 1"M |
17.8×3.5 |
10.75×4.5×2 |
12 |
| SP320-HO |
34 |
128.7 |
13 |
49.2 |
36 |
1 |
22.8×3.5 |
10.75×4.5×2 |
15 |
| SP410-HO |
45 |
170.3 |
18 |
68.1 |
45 |
1 |
26.0×3.5 |
10.75×4.5×2 |
17 |
| SP600-HO |
60 |
227.1 |
26 |
98.4 |
65 |
1 |
30.7×3.5 |
10.75×4.5×2 |
19 |
| SP740-HO |
60 |
227.1 |
31 |
117.3 |
80 |
1 |
39.4×3.5 |
10.75×4.5×2 |
24 |
| SP950-HO |
60 |
227.1 |
39 |
147.6 |
100 |
1 |
47.6×3.5 |
10.75×4.5×2 |
29 |
Models listed above are 90-265v/50-60Hz with Standard North American 3 Prong Grounded Power Cord. For other power cord type, use appropriate suffix: Continental European 2-pin power = /2, •UK 3 Prong Grounded = /2B • Australian 3 Prong Grounded = /2A • No Connector "Bare Leads" = NC. Example: SP100-HO/2B = British Power Cord.
*Flow rates and dose stated at 95% UVT10
Sterilight Platinum Series Replacement Parts
| For System |
UV Lamp, Sterilume™ |
Quartz Sleeve |
Flow Restrictor (For SPV Only) |
| SP100-HO |
S100RL-HO |
QS-100 |
|
| SP150-HO & SPV-200 |
S150RL-HO |
QS-150 |
FRSS-2.5 |
| SP200-HO |
S200RL-HO |
QS-200 |
|
| SP320-HO |
S320RL-HO |
QS-320 |
FRSS-6 |
| SP410-HO & SPV-410 |
S410RL-HO |
QS-410 |
FRSS-8 |
| SP600-HO & SPV-600 |
S600RL-HO |
QS-600 |
FRSS-12 |
| SP740-HO & SPV-740 |
S740RL-HO |
QS-740 |
FRSS-15 |
| SP950-HO & SPV-950 |
S950RL-HO |
QS-950 |
|
All Replacement lamps & sleeves come with 2 O-rings
| Model No. |
For System |
Description |
| SPCICEHO |
All |
Controller, Platinum Ice |
| 254NM-FP2 |
All 'SPV' |
UV-Sensor Assembly, Flow-Pace™ 254nm for NSF Certified Systems, w/3' Sensor Cable |
| 254NM-FP1 |
All 'HO' |
UV Sensor Assembly, Flow-Pace™ 254nm for Non-Validated Systems, w/3' Sensor Cable |
| OR-12N |
All |
O-Ring for Sensor Assembly |
| RN-001 |
All |
Retaining Nut, Noryl (replaces Aluminum) |
| OR-212 |
All |
O-Ring for Quartz Sleeve/Aluminum/Noryl Nuts |
| SP008 |
All |
Quartz Sleeve Spring |
| 410076 |
All |
3 1/2" Clamp |
Discontinued Sterilight (R-Can) Platinum Series UV Systems - NSF Certified
Please note that this product line has recently changed changed and the below systems are no longer available. The below information is shown for cross-reference and support for existing products only. Replacement parts will still be available through at least 2015.
| OLD Model # |
Closest Model Replacement (check tables above for specs:) |
Flow Rate* |
Lamp Watts |
Inlet/Outlet Connection, MNPT (In.) |
Dimensions, Inches |
Weight Lbs. |
| GPM |
L/Min |
Chamber (L"xD") |
Controller (L"xW"xH") |
| SPV-1.5 |
No Replacement |
1.5 |
5.7 |
15 |
1/2 |
13.8×3.5 |
10.75×4.5×2 |
11 |
| SPV-2.5 |
SPV-200 |
2.5 |
9.5 |
20 |
1/2 |
15.8×3.5 |
10.75×4.5×2 |
12 |
| SPV-3.5 |
No Replacement |
3.5 |
13.2 |
30 |
1/2 |
17.8×3.5 |
10.75×4.5×2 |
13 |
| SPV-6 |
SPV-410 |
6.0 |
22.7 |
36 |
3/4F, 1M |
22.8×3.5 |
10.75×4.5×2 |
16 |
| SPV-8 |
SPV-600 |
8.0 |
30.3 |
45 |
3/4F,1M |
26.0×3.5 |
10.75×4.5×2 |
18 |
| SPV-12 |
SPV-740 |
12.0 |
45.4 |
65 |
3/4F,1M |
30.7×3.5 |
10.75×4.5×2 |
20 |
| SPV-15 |
SPV-950 |
15.0 |
56.8 |
80 |
3/4F,1M |
39.4×3.5 |
10.75×4.5×2 |
25 |
| SPV-20 |
No replacement |
20.0 |
75.7 |
100 |
3/4F,1M |
47.6×3.5 |
10.75×4.5×2 |
30 |
|