R-Can Sterilight Platinum Series Ultraviolet
(UV) Systems
R-Can Sterilight Platinum Ultraviolet system is designed to
optimize the fluid flow path and ensure the ultraviolet light is efficiently and
uniformly delivered to any microbiological organism residing in the water. The
Platinum reactor's unique flow distributor ensures that the water follows the
most optimum path in its region, eliminating the short circuit flow path created
by uneven flow within the reactor.
 |
System
Tested and Certified by NSF International against NSF Standard 55
for Disinfection Performance, Class A
Models: SPV-1.5, SPV-2.5, SPV-3.5, SPV-6, SPV-8, SPV-12,
SPV-15, SPV-20 |
|
 |
|
Features of the
R-Can Platinum Ice Controller
- 90-265 VAC universal operation
- Visual UV intensity reading (reads in % UV output)
- Visual elapsed time meter - displays remaining lamp
life and total controller running time.
- Constant current output over entire line voltage
- Active power factor correction
- EMI/RFI filtering (meets new CE directives)
- One controller to drive all lamps
- Isolated power source for alarm system
- True lamp current detection
- Full diagnostic check on start-up
- Separate fuse protection for controller circuit.
- Dry contacts (for solenoid, lamps, audible alarms,
etc.)
- RJ-11 communication port (sensor output & future RG
remote alarm package)
- Universal IEC power input connector
Additional Features of R-Can Platinum Series
- Safety-Loc™ Connector -
Interlock switch
molded into the lamp connector, preventing lamp operation when the lamp is
not fully inserted into the reactor chamber. This connector is keyed to the
reactor chamber, allowing for the correct lamp orientation within the
reactor, eliminating potentially false sensor readings.
- Flow-Pace™ UV Sensor -
254nm sensor capable of
detecting a low-flow condition and automatically adjust the lamp power to
the water flow, resulting in lower power consumption, reduced operational
costs & less heat transfer into the water.
- Sterilume™ Lamps -
Sterilight's low pressure
high output lamp offering consistent UV output over the life of the lamp.
|
|
|
|
Flow Distributor
Above image shows water track path lines as they go through the flow distributor |
|
|
|
Flow Distributor Comparison
Above image shows water track lines with no flow distributor |
|
|
|
|
Platinum System
|
|
|
|
Platinum Ice Controller
|
|
|
|
|
Flow-Pace™ UV Sensor
|
|
|
|
Safety-Loc™ Connector
|
|
|
|
R-Can Platinum Series UV Systems - NSF Certified - 316 SS
Please note that this product line has
recently changed changed. The newest information is in this table.
The cross reference information and specifications for the old part #'s.
are listed at the bottom of this page. Click here to skip to that section.
|
New Model # |
Replaces Model # |
Flow Rate* |
Lamp Watts |
Inlet/Outlet Connection, MNPT (In.) |
Dimensions, Inches |
Weight Lbs. |
|
GPM |
L/Min |
Chamber (L"xD") |
Controller (L"xW"xH") |
|
SPV-200 |
SPV-2.5 |
2.6 |
9.8 |
30 |
1/2 |
15.8×3.5 |
10.75×4.5×2 |
12 |
|
SPV-410 |
SPV-6 |
6.0 |
22.7 |
36 |
3/4F, 1M |
22.8×3.5 |
10.75×4.5×2 |
16 |
|
SPV-600 |
SPV-8 |
8.0 |
30.3 |
45 |
3/4F,1M |
26.0×3.5 |
10.75×4.5×2 |
18 |
|
SPV-740 |
SPV-12 |
12.0 |
45.4 |
65 |
3/4F,1M |
30.7×3.5 |
10.75×4.5×2 |
20 |
|
SPV-950 |
SPV-15 |
15.0 |
56.8 |
80 |
3/4F,1M |
39.4×3.5 |
10.75×4.5×2 |
25 |
Models listed above are 90-265v-50-60Hz
w/Std North American 3 Prong Grounded Power Cord. For other power cord type, use
appropriate suffix below:
Continental European 2-pin power =
/2, • UK
3 Prong Grounded = /2B, • Australian 3 Prong Grounded = /2A • No Connector "Bare
Leads" = NC, Example: SPV-1.5/2B = British Power Cord.
*Flow rates stated as determined by NSF
Standard 55 testing. (40 mJ/cm² @ UVT>75% @ fall-safe point).
Please note that the NSF/ANSI Certified systems above contain a flow restrictor
to limit the flow at the certified level.
R-Can Platinum Series UV Systems - Non NSF Certified - 304 SS
|
Model # |
Flow Rate * |
Lamp Watts |
Inlet/Outlet Connection MNPT (In.) |
Dimensions, Inches |
Weight Lbs. |
|
@ 16 mJ/cm² |
@ 40 mJ/cm² |
Chamber (L" x D") |
Controller (L"xW"xH") |
|
GPM |
L/Min |
GPM |
L/Min |
| SP100-HO |
11 |
41.6 |
4 |
15.1 |
15 |
3/4F, 1"M |
13.8×3.5 |
10.75×4.5×2 |
10 |
| SP150-HO |
14 |
53.0 |
6 |
22.7 |
20 |
3/4F, 1"M |
15.8×3.5 |
10.75×4.5×2 |
11 |
|
SP200-HO |
20 |
75.7 |
8 |
30.3 |
30 |
3/4F, 1"M |
17.8×3.5 |
10.75×4.5×2 |
12 |
| SP320-HO |
34 |
128.7 |
13 |
49.2 |
36 |
1 |
22.8×3.5 |
10.75×4.5×2 |
15 |
| SP410-HO |
45 |
170.3 |
18 |
68.1 |
45 |
1 |
26.0×3.5 |
10.75×4.5×2 |
17 |
| SP600-HO |
60 |
227.1 |
26 |
98.4 |
65 |
1 |
30.7×3.5 |
10.75×4.5×2 |
19 |
| SP740-HO |
60 |
227.1 |
31 |
117.3 |
80 |
1 |
39.4×3.5 |
10.75×4.5×2 |
24 |
| SP950-HO |
60 |
227.1 |
39 |
147.6 |
100 |
1 |
47.6×3.5 |
10.75×4.5×2 |
29 |
Models listed above are 90-265v/50-60Hz
with Standard North American 3 Prong Grounded Power Cord. For other power cord
type, use appropriate suffix: Continental European 2-pin power = /2, •UK 3 Prong
Grounded = /2B • Australian 3 Prong Grounded = /2A • No Connector "Bare Leads" =
NC. Example: SP100-HO/2B = British Power Cord.
*Flow rates and dose stated at 95% UVT10
R-Can SPV Series Replacement Parts
| For System |
UV Lamp,
Sterilume™ |
Quartz Sleeve |
Flow
Restrictor |
| SPV1.5 |
S100RL-HO |
QS-100 |
FRSS-1.5 |
| SPV2.5 |
S150RL-HO |
QS-150 |
FRSS-2.5 |
| SPV3.5 |
S200RL-HO |
QS-200 |
FRSS-3.5 |
| SPV6 |
S320RL-HO |
QS-320 |
FRSS-6 |
| SPV8 |
S410RL-HO |
QS-410 |
FRSS-8 |
| SPV12 |
S600RL-HO |
QS-600 |
FRSS-12 |
| SPV15 |
S740RL-HO |
QS-740 |
FRSS-15 |
| SPV20 |
S950RL-HO |
QS-950 |
FRSS-20 |
|
SP950HO |
S950RL-HO |
QS-950 |
-- |
|
| For System |
UV Lamp,
Sterilume™ |
Quartz Sleeve |
| SP100-HO |
S100RL-HO |
QS-100 |
|
SP150-HO |
S150RL-HO |
QS-150 |
| SP200-HO |
S200RL-HO |
QS-200 |
|
SP320-HO |
S320RL-HO |
QS-320 |
| SP410-HO |
S410RL-HO |
QS-410 |
|
SP600-HO |
S600RL-HO |
QS-600 |
| SP740-HO |
S740RL-HO |
QS-740 |
|
SP950-HO |
S950RL-HO |
QS-950 |
|
All Replacement lamps & sleeves come
with 2 O-rings
| Model No. |
For System |
Description |
| SPCICEHO |
All |
Controller, Platinum Ice |
|
254NM-FP2 |
All 'SPV' |
UV-Sensor Assembly, Flow-Pace™
254nm for NSF Certified Systems, w/3' Sensor Cable |
| 254NM-FP1 |
All 'HO' |
UV Sensor Assembly, Flow-Pace™
254nm for Non-Validated Systems, w/3' Sensor Cable |
|
OR-12N |
All |
O-Ring for Sensor Assembly |
| RN-001 |
All |
Aluminum Retaining Nut |
|
OR-212 |
All |
O-Ring for Quartz Sleeve/Aluminum
Nuts |
| SP008 |
All |
Quartz Sleeve Spring |
|
410076 |
All |
3 1/2" Clamp |
Discontinued R-Can Platinum Series UV Systems
- NSF Certified
Please note that this product line has
recently changed changed and the below systems are no longer available.
The below information is shown for cross-reference and support for existing
products only. Replacement parts will still be available through at least
2015.
|
OLD Model # |
Closest Model Replacement (check
tables above for specs:) |
Flow Rate* |
Lamp Watts |
Inlet/Outlet Connection, MNPT (In.) |
Dimensions, Inches |
Weight Lbs. |
|
GPM |
L/Min |
Chamber (L"xD") |
Controller (L"xW"xH") |
|
SPV-1.5 |
No Replacement |
1.5 |
5.7 |
15 |
1/2 |
13.8×3.5 |
10.75×4.5×2 |
11 |
|
SPV-2.5 |
SPV-200 |
2.5 |
9.5 |
20 |
1/2 |
15.8×3.5 |
10.75×4.5×2 |
12 |
|
SPV-3.5 |
No Replacement |
3.5 |
13.2 |
30 |
1/2 |
17.8×3.5 |
10.75×4.5×2 |
13 |
|
SPV-6 |
SPV-410 |
6.0 |
22.7 |
36 |
3/4F, 1M |
22.8×3.5 |
10.75×4.5×2 |
16 |
|
SPV-8 |
SPV-600 |
8.0 |
30.3 |
45 |
3/4F,1M |
26.0×3.5 |
10.75×4.5×2 |
18 |
|
SPV-12 |
SPV-740 |
12.0 |
45.4 |
65 |
3/4F,1M |
30.7×3.5 |
10.75×4.5×2 |
20 |
|
SPV-15 |
SPV-950 |
15.0 |
56.8 |
80 |
3/4F,1M |
39.4×3.5 |
10.75×4.5×2 |
25 |
|
SPV-20 |
No replacement |
20.0 |
75.7 |
100 |
3/4F,1M |
47.6×3.5 |
10.75×4.5×2 |
30 |
|