| Type
|
Volume, Gallons (Vol) |
Medium Flow (MF) |
High Flow (HF) |
| 4" x 40" |
2.5 |
4 |
10 |
| 4" Magnum |
3.5 |
4 |
10 |
| 6" x 40" |
4.0 |
12 |
20 |
| 8" x 40" |
6.0 |
25 |
35 |
| 8" Magnum |
8.5 |
25 |
35 |
Estimate of
Cleaning Solution Volume
V = El × Vol
× 5
Estimate of Total Flow Required
HTF = NV × HF
MTF = NV × MF
-
HTF = High Total Flow
-
MTF = Medium Total Flow
-
NV = Number of Vessels in Parallel
-
HF = High Flow from Flow Table
-
MF = Medium Flow from Flow Table