VIQUA Sterilight "Copper" (SC) Ultraviolet (UV) Disinfection Systems
| VIQUA (R-Can) Sterilight “Copper” ultraviolet disinfection systems are specifically designed for point-of-use applications where microbiological control is required. Sterilight “Copper” UV units control bacteria, virus and protozoan cyst (specifically giardia lamblia and cryptosporidium) all in one complete design.
Features & Specifications VIQUA Sterilight UV Systems
-
99.99% destruction of bacteria, virus & protozoan cysts (Giardia lamblia & Cryptosporidium) at rated flow.
-
304 Stainless Steel reactors with 600 grit polish (A249 pressure rating tube)
-
Sterilume-EX hard glass, coated lamps with 9000 hour lamp life
-
214 fused quartz sleeves with fire polished end
-
Integral ballast and lamp connector with LED power/lamp on indicator and 5’ lamp cord
-
½” MNPT/ ⅜” FNPT combination ports
-
Maximum Operating Pressure: 125 psi (8.62 bar)
-
Ambient Temperature: 36-104°F (2-40°C)
-
Reactor Chamber Material: 304 SS
|

|
Sterilight "Copper Series" Ultraviolet Water Disinfection Systems
110-130v, 50-60Hz USA
Voltage |
|
| Model # |
Flow Rate * |
Lamp Watts |
Power Consumption |
Dimensions, Inches |
Weight Lbs. |
@ 16 mJ/cm² |
@ 40 mJ/cm² |
Length |
Cell Dia. |
GPM |
L/Min |
GPM |
L/Min |
| SC1 |
2.0 |
7.5 |
0.5 |
2.0 |
10W |
12W |
13.5 |
2.5 |
4 |
| SC2.5 |
4.2 |
15.9 |
1.9 |
7.2 |
14W |
16W |
16.5 |
2.5 |
4.5 |
| SC4 |
7.5 |
28.4 |
2.8 |
10.6 |
17W |
19W |
18.2 |
2.5 |
6.5 |
*Flow Rates listed are dose dependant. 40 mJ/cm2 = NSF/EPA Standard. 16 mJ/cm2 = US Public Health Standard
Sterilight "Copper Series" Ultraviolet Water Disinfection Systems
200-250v/50-60Hz European Voltage |
|
| Model # |
Flow Rate * |
Lamp Watts |
Power Consumption |
Dimensions, Inches |
Weight Lbs. |
@ 16 mJ/cm² |
@ 40 mJ/cm² |
Length |
Cell Dia. |
GPM |
L/Min |
GPM |
L/Min |
| SC1/2 |
2.0 |
7.5 |
0.5 |
2.0 |
10W |
12W |
13.5 |
2.5 |
4 |
| SC2.5/2 |
4.2 |
15.9 |
1.9 |
7.2 |
14W |
16W |
16.5 |
2.5 |
4.5 |
| SC4/2 |
7.5 |
28.4 |
2.8 |
10.6 |
17W |
19W |
18.2 |
2.5 |
6.5 |
*Flow Rates listed are dose dependant. 40 mJ/cm2 = NSF/EPA Standard. 16 mJ/cm2 = US Public Health Standard
Replacement Parts for Sterilight Ultraviolet UV Systems
| For System |
UV Lamp |
Quartz Sleeve |
| SC1 |
S212RL |
QS-212D |
| SC2.5 |
S287RL |
QS-287D |
| SC4 |
S330RL |
QS-330D |
|
| Model No. |
Description |
| BA-C1 |
Ballast for Copper 100-130V |
| BA-C2 |
Ballast for Copper 200-250V |
|
Sterilight UV Systems Technical Information
Note: Microorganisms require varying UV dose levels for destruction. Some of the common organisms and their corresponding dosage level are shown below.
| Microorganism |
Dose (mJ/cm²) |
| E. Coli² |
6.6 |
| Cryptosporidium parvum¹ |
<10 |
| Giardia lamblia¹ |
<10 |
| Hepatitus Virus¹ |
8 |
| Influenza Virus¹ |
6.6 |
| Shigella dysenteriae² |
4.2 |
| Legionella pnuemophila² |
3.8 |
| Salmonella paratyphi² |
6.1 |
1. 2-log reduction.
2. 4-log reduction |
|
 |
|
For prompt, courteous and reliable service, contact us today! |
Copyright © 2010 Applied Membranes, Inc. All Rights Reserved