order to have some measure of the degree of this fouling problem, a concept
called Silt Density Index is used.
Here a 0.45 micron filter is exposed to the feed water under pressure and
filtration rates are calculated.
A detailed description of the test is available in our design information
section - Click
here to view the description. An SDI of less than 5 is considered acceptable for the reverse osmosis systems. This means that at values of SDI of less than 5, the membranes should foul at a very low rate. Even though the concept works most of the time, there are exceptions when a lower SDI (less than 3) is desirable due to the nature of the suspended solids in that feed water. |
|