Platinum Series UV Systems – NSF Certified – 316 SS
Retired Model | Suggested Replacement | Comparison of Retired part and Suggested Replacement | ||||
Flow Rate, GPM (Retired/ Replacement) |
Inlet/Outlet (Retired/ Replacement) |
Chamber Dimensions (Retired/ Replacement) |
Monitored (Retired/ Replacement) |
NSF Certified (Retired/ Replacement) |
||
SPV-200 | n/a | 2.6/(n/a) | ½” MNPT/(n/a) | 17.8" × 3.5" /(n/a) | YES/YES | YES/n/a |
SPV-410 | n/a | 6/(n/a) | ¾”F-1”M/(n/a) | 26.0" × 3.5" /(n/a) | YES/YES | YES/n/a |
SPV-600 | PRO10 | 8/10 | ¾”F-1”M/ 1"F-1¼"M | 30.7 × 3.5/ 22"x4" | YES/YES | YES/YES |
SPV-740 | PRO10 | 12/10 | ¾”F-1”M/ 1"F-1¼"M | 39.4 × 3.5/ 22"x4" | YES/YES | YES/YES |
SPV-950 | PRO20 | 15/20 | ¾”F-1”M/ 1"F-1¼"M | 44.5 × 3.5/ 31"x4" | YES/YES | YES/YES |
Platinum Series UV Systems – 304SS (Non-Listed)
Retired Model | Suggested Replacement | Comparison of Retired part and Suggested Replacement | |||||
Flow Rate, 16 mJ/cm2 GPM (Retired/ Replacement) |
Flow Rate, 40 mJ/cm2 GPM (Retired/ Replacement) |
Inlet/Outlet (Retired/ Replacement) |
Chamber Dimensions (Retired/ Replacement) |
Monitored (Retired/ Replacement) |
NSF Certified (Retired/ Replacement) |
||
SP320-HO | VH410M | 34/34 | 13/14 | ¾”F-1”M/ ¾”F-1”M | 22.8"×3.5"/ | YES/YES | NO/NO |
SP410-HO | VH410M | 45/34 | 18/14 | 1"MNPT/ ¾”F-1”M | 26.0"×3.5"/ | YES/YES | NO/NO |
SP-600HO | VP600M | 60/40 | 26/22 | 1"MNPT/ 1" MNPT | 30.7"×3.5"/ | YES/YES | NO/NO |
SP-740HO | VP950M | 60/60 | 31/35 | 1½"MNPT/ 1½"MNPT | 39.4"×3.5"/ | YES/YES | NO/NO |
SP-950HO | VP950M | 60/60 | 39/35 | 1½"MNPT/ 1½"MNPT | 44.5"×3.5"/ | YES/YES | NO/NO |
Parts
Replacement Parts for Sterilight Platinum Series UV Ultraviolet Systems
For Sterilight System |
UV Lamp, Sterilume™ |
Quartz Sleeve |
|
SP320-HO |
S320RL-HO |
QS-320 |
|
SP410-HO & SPV-410 |
S410RL-HO |
QS-410 |
|
SP600-HO & SPV-600 |
S600RL-HO |
QS-600 |
|
SP740-HO & SPV-740 |
S740RL-HO |
QS-740 |
|
SP950-HO & SPV-950 |
S950RL-HO |
QS-950 |
|
Note: Replacement lamps and sleeves come with 2 O-Rings |
Part Number |
For Sterilight System |
Description |
SPC-ICE-HO |
ALL |
Controller, Platinum Ice |
254NM-FP2 |
ALL “SPV” |
UV Sensor Assembly, Flow-Pace™ 254nm for NSF Certified Systems, w/3’ Sensor Cable |
254NM-FP1 |
ALL “HO” |
UV Sensor Assembly, Flow-Pace™ 254nm for Non-Validated Systems, w/3’ Sensor Cable |
OR-12N |
ALL |
O-Ring for Sensor Assembly |
RN-001 |
ALL |
Aluminum Retaining Nut |
OR-212 |
ALL |
O-Ring for Quartz Sleeve/Aluminum Nuts |
SP008 |
ALL |
Quartz Sleeve Spring |
410076 |
ALL |
3 ½” Clamp |
Literature
Downloadable Literature for Sterilight Platinum Series UV Ultraviolet Systems
Ultraviolet Disinfection Technical Information
Note: Microorganisms require varying UV dose levels for destruction. Some of the common organisms and their corresponding dosage level are shown below.
1. 2-log reduction, 2. 4-log reduction
Contact us
for a quote or for any additional information
or call us at 1.800.321.9321