Signet Instruments for Commercial RO Systems
Automation Made Easy
+GF+ Signet Panel and Field Mount Transmitters and Sensors for monitoring Flow, pH, Conductivity, Level, Temperature and various water quality parameters in a RO, UF, MF, NF, SWRO, or other Water Treatment Systems.
Request A Quote »Benefits
Benefits of Signet Water Quality Instruments
- Accurate measurement is the basis for reliable process control
- Most sensors are available in plastic and are therefore highly resistant to chemicals.
- Plug-and-play measurement products are self-explanatory, easy to maintain and are offered with suitable installation fittings.
Details
Signet Water Quality Instruments Details & Ordering Information
Model No. |
Description |
Range |
SIGNET 8850 CONDUCTIVITY/TDS/RESISTIVITY TRANSMITTERS |
||
3-8850-1P |
Panel Mount Transmitter – One input with 4-20mA output and one open collector; uses 2 wire power |
N/A |
3-8850-1 |
Field Mount Transmitter - One input with 4-20mA output and one open collector; uses 2 wire power |
N/A |
SIGNET 2818-2823 CONDUCTIVITY/TDS/RESISTIVITY ELECTRODES (for Field or Panel Mount Transmitters) |
||
3-2819-1 |
Sensor - Cell Constant ( 0.01) |
0-20 MΩ |
3-2820-1 |
Sensor - Cell Constant ( 0.1) |
0-100 PPM |
3-2821-1 |
Sensor - Cell Constant ( 1.0) |
100-10,000 PPM |
3-2822-1 |
Sensor - Cell Constant ( 10) |
10,000-50,000 PPM |
SIGNET 2850 CONDUCTIVITY/TDS/RESISTIVITY INTEGRAL BLIND TRANSMITTERS |
||
3-2850-52-39 |
Integral Transmitter/ Sensor - Cell Constant ( 0.01) |
0-20 MΩ |
3-2850-52-40 |
Integral Transmitter/ Sensor - Cell Constant ( 0.1) |
0-100 PPM |
3-2850-52-41 |
Integral Transmitter/ Sensor - Cell Constant ( 1.0) |
100-10,000 PPM |
3-2850-52-42 |
Integral Transmitter/ Sensor - Cell Constant ( 10) |
10,000-50,000 PPM |
SIGNET 8750 pH/ORP SIGNET PANEL AND FIELD MOUNT TRANSMITTERS |
||
3-8750-1P |
Panel Mount Transmitter – One input with 4-20mA output and one open collector; uses 2 wire power |
N/A |
3-8750-1 |
Field Mount Transmitter – One input with 4-20mA output and one open collector; uses 2 wire power |
N/A |
SIGNET 2724, 2725 pH/ORP ELECTRODES (for Field or Panel Mount Transmitters) |
||
3-2724-10* |
pH Sensor - Flat Glass |
0-14 pH |
3-2725-60* |
ORP Sensor - Flat Glass |
(-)2,000 – 2,000 mV |
SIGNET 2750 & 2760 pH/ORP PREAMPLIFIERS |
||
3-2750-2 |
Transmitter/Preamp |
N/A |
3-2760-11 |
pH/ORP Preamplifier, In-Line, ¾” NPT Threads, 15 ft. cable |
N/A |
SIGNET 8550 ProcessPRO FLOW TRANSMITTERS |
||
3-8850-1P |
Panel Mount Transmitter – One input with 4-20mA output and one open collector; uses 2 wire power |
N/A |
3-8850-1 |
Field Mount Transmitter – One input with 4-20mA output and one open collector; uses 2 wire power |
N/A |
SIGNET FLOW TRANSMITTER SENSORS |
||
3-2536-P0* |
2536 Rotor-X Paddlewheel Flow Sensor (Blue) |
66:1 Turndown R2t:0 |
P51530-P0* |
515 Rotor-X Paddlewheel Flow Sensor (Red) |
20:1 Turndown R2t:0 |
3-2537-6C-P0 |
2537 Paddlewheel Blind Flow Sensor |
N/A |
Pressure Noshok Blind Transmitters |
||
100-150-1-1-2-7 |
Pressure Noshok Blind Transmitter |
0-150 PSI |
100-500-1-1-2-7 |
Pressure Noshok Blind Transmitter |
0-500 PSI |
100-1500-1-1-21 |
Pressure Noshok Blind Transmitter |
0-1500 PSI |
Turbidimeters Hach |
||
6010100 |
1720E Turbidimeter with SC100 Controller |
0-100 NTU |
6010101 |
1720E Turbidimeter Only |
0-100 NTU |
*Installation Tees are sold separately for parts marked with an asterisk. (See parts tab for ordering information)
Features
Signet Water Quality Instruments Features
Features of Signet Water Quality Instruments Include:
- Back Panel Mount and Field Mount configurations available
- Integral mount systems for quick and easy installation
- Compact design for maximum installation flexibility
- Multiple measurement parameters display options
- Simulate function
- Programmable temperature compensation
- Dual output option allows temperature and process signal transmission
- NEMA 4X/IP65 enclosure with self-healing window
- EasyCal with automatic test solution
- CE Certified
- UL and CUL Certified
- FCC Certified
- RoHS and China RoHS Compliant
Refer to the manufacturer specifications in the Literature Tab for specific product details
Applications
Applications for Signet Water Quality Instruments
|
|
|
Parts
Installation Tees for Signet Water Quality Instruments
5911.005 |
0.5” Installation Tee, PVC |
|
5911.007 |
0.75” Installation Tee, PVC |
|
5911.010 |
1.0” Installation Tee, PVC |
|
5911.015 |
1.5” Installation Tee, PVC |
|
5911.120 |
2.0” Installation Tee, PVC |
|
5911.130 |
3.0” Installation Tee, PVC |
|
5911.140 |
4.0” Installation Tee, PVC |
Related Water Quality Monitoring Products
Literature
Manufacturer Specifications for GF Signet Water Quality Instruments
- Signet 8850 Conductivity Resistivity Transmitters Data Sheet
- Signet 2818-2823 Conductivity Resistivity Electrode Sensors Data Sheet
- Signet 2850 ConductivityResistivity Sensor Data Sheet
- Signet 8750 pH & ORP Transmitters Data Sheet
- Signet 2724-2726 pH & ORP Electrodes Data Sheet
- Signet 2750 DryLoc pH & ORP Preamplifier Datasheet
- Signet 2760 DryLoc pH & ORP Preamplifier Datasheet
- Signet 8550 Flow Transmitter Datasheet
- Signet 2536 Rotor-X Paddlewheel Flow Sensors Datasheet
- Signet 515-2536 Rotor-X Flow Sensors Datasheet
- Signet 2537 Paddlewheel Flow Sensor Datasheet
- AMI Commercial Components Catalog