XL Series - Low Energy RO Systems 2,000 to 10,000 GPD
Designed to produce low dissolved solids water from tap or well water, these small commercial Low Energy RO systems use extra low energy XLE reverse osmosis membranes which run at 100-140 psi. The product water is used in applications such as spot free rinse, water stores, whole house, labs, ice makers, humidification, misting and a wide variety of other applications.
Part of the L-series family (other systems include L and HL series), these complete reverse osmosis systems are best suited for water of less than 1,000 PPM total dissolved solids (TDS). The systems use proven, reliable components and are mounted on a sturdy powder-coated metal frame. There are numerous design details, learned from years of experience that are incorporated in our systems. Our process and fluid design ensures an optimum membrane life and minimizes the membrane fouling.
Request A Quote »Benefits
- Significantly reduce your operating cost with the use of Low Energy RO Systems using XLE RO Membranes
- Over 40 years of experience is reflected in our quality
- Compact, Heavy Duty, Powder Coated Frame
- Proven components used throughout the RO system
- Conservatively engineered for reliable long term performance
- Factory tested to ensure trouble-free operation
Details
Model No. |
System Capacity |
Qty. of 4x40 Membrane Elements (XLE) |
Line Sizes |
System Dimensions |
Approx. Shipping Weight |
|||||
GPD |
m³/day |
Inlet |
Perm. |
Conc. |
Length |
Depth |
Height |
|||
XL-14A-216 |
2,000 |
7.5 |
1 |
¾ |
½ |
½ |
20/51 |
28/71 |
54/137 |
275/125 |
XL-24A-216 |
4,000 |
15 |
2 |
¾ |
½ |
½ |
20/51 |
28/71 |
54/137 |
300/136 |
XL-34A-216 |
5,800 |
22 |
3 |
¾ |
½ |
½ |
20/51 |
28/71 |
54/137 |
325/147 |
XL-44A-216 |
7,500 |
28 |
4 |
¾ |
½ |
½ |
20/51 |
34/87 |
54/137 |
350/159 |
XL-54A-216 |
9,000 |
34 |
5 |
¾ |
½ |
½ |
20/51 |
34/87 |
54/137 |
375/170 |
XL-64A-216 |
10,000 |
38 |
6 |
¾ |
½ |
½ |
20/51 |
34/87 |
54/137 |
400/181 |
Notes and Voltage/ Ordering Information
- All dimensions and weights are approximate.
- Capacity Basis: 24 hrs/day
- Systems rated at: 77°F (25°C) using 1,000 ppm sodium chloride solution operating at approx. 200 psi pressure. System capacity changes significantly with water temperature. For higher TDS a water analysis must be supplied and could result in modifications to the system or changing from XL to L or HL series system.
- Minimum feed pressure to RO System: 40-60 PSI.
- Chlorine must be removed with a carbon filter or with chemical injection prior to the RO system, if present in feed water.
- Pretreatment for water hardness using a softener should be added to avoid scaling the membranes.
- Feed water turbidity: Less than 1 NTU; Feed water silt density index (SDI): 3 maximum. If exceeded, pretreatment with media filter recommended. All pretreatment equipment and SDI test kits are available from Applied Membranes.
- Voltage Codes: 216 = 220 -240v/ 1ph/ 60hz • 215 = 220-240v/1ph/50hz .
Three phase or other voltages not available with XL Series. See Series L or HL.
Features
Standard Equipment
|
|
Microprocessor Controller for Automatic Operation
Parts
Optional Add-On Parts and Equipment for Low Energy Commercial RO Systems
AMI's XL Series Energy Saving RO Systems are available with a wide variety of optional add-on equipment. All assemblies include hardware and mounting equipment for easy upgrade to your new or existing system installation.
Wall Mount Filter Cartridges
Includes mounting bracket and Isolation Valves to close the line when changing the filter cartridge.
Part # A711
Filter cartridge must be ordered separately - common options are shown below. Any 20" Big Blue size cartridge can be installed. Click here to view our complete filter cartridge product selection.
Pretreatment Options Available:
- Sediment Filters in a variety of micron ratings -
- Scale Inhibitor Cartridges: H-F4220-NS
- Block Carbon Filter Cartridges Block Carbon filter cartridges produce no carbon fines.
- KX Brand: 32-425-125-20. Click for Product Details
Post-treatment Options Available:
- Calcite Filter Cartridge to neutralize the pH of the RO permeate water - Filter Model H-F4220CALCITE Click for Product Details
- DI Filter Cartridge with Mixed-Bed Deionization Resin for ultrapure applications - Filter Model: H-F4220DI Click for Product Details
Softeners & Media Filtration Pre/Post Treatment
AMI Media filters feature fully automatic backwash or regeneration for easy, trouble free maintenance. Ensure superior system operation and extended membrane life by providing proper pretreatment to the incoming feed water on a continuous basis. Common pretreatment or post-treatment methods include:
- Single or Twin Water Softener to remove hardness and scale.
- Multi-Media Filter for sediment filtration to approximately 10 microns.
- Carbon Filter to remove chlorine.
- Calcite Filter to neutralize the pH of the RO product water.
Click Here to visit the Media Filtration section of our site for detailed information on the full line of media filtration products we carry.
Chemical Injection System
Antiscalant injection as an alternative to a water softener for scale control, or
Sodium Metabisulfite injection as an alternative to a carbon filter to remove chlorine.
Water Quality Monitors
Pre-packaged wall-mountable water quality monitoring controls allow you to monitor the quality of the incoming feed or RO product water. Assembly includes the monitor, enclosure and sensor.
Available Options for Monitoring Incoming Feed Water Quality:
- ORP - 60Hz Part # A246, 50Hz Part # A247
- pH - 60Hz Part # A244, 50Hz Part # A245
Available Options for Monitoring RO Product Water Quality:
- Total Dissolved Solids (TDS) - 60Hz Part # A242, 50Hz Part # A243
- Resistivity - 60Hz Part # A248, 50Hz Part # A249
- pH - 60Hz Part # A244, 50Hz Part # A245
Ultraviolet (UV) Systems
Add an ultraviolet water sterilizer for a 99.9% reduction of bacteria and viruses in the feed and/or permeate line.
Note: For feed line, wall-mount filter cartridge assembly shown above is required.
Tank Pressure Controls
To automatically turn the RO system on or off with the permeate storage tank level. For use with a pressurized storage tank (sold separately).
- 220v/60Hz - Part # A621
Pressurized Storage Tank
Pressurized permeate storage tank available in 40 or 80 gallon volume. Assembly includes tank, valve, piping, tubing, and pressure gauge.
- 40 Gallon Tank Assembly - Part # A612-40
- 80 Gallon Tank Assembly - Part # A612-80
Tank Level Controls
Turns system on or off according to the water level in an atmospheric storage tank.
- Dual float assembly provides system on/off controls.
Part # YFL2PPAS - Triple float assembly provides system on/off as well as low level protection on/off for a repressurization pump.
Part # YFL3PPAS
Atmospheric storage tank and repressurization pump are sold separately.
Atmospheric Storage Tank
Atmospheric Permeate Storage tank. Assembly includes bulkheads and vent filter. For use with Tank Level Controls (sold separately).
- 200 Gallon Part # A613-200
- 400 Gallon Part # A613-500
Delivery System
20 GPM, 50 PSI, 220v/1ph/50-60Hz
Includes Pump, 40 Gallon Pressure Tank, Controls and Fittings
Part # A606-216
Prefilter Pressure Gauge
To allow for monitoring of the in and out pressure of the prefilter in order to indicate when the cartridge needs to be changed. Assembly includes pressure gauge and fittings.
Part # A623
Floor Casters Kit
2 Locking casters and 2 Swivel casters to mount at the base of the stand for ease of system mobility.
Part #: A625
Replacement Parts & Consumables for HL Series Reverse Osmosis Systems
- Replacement Reverse Osmosis Membranes for Commercial RO Systems
- Replacement Membrane Pressure Vessels for Commercial RO Systems
- Replacement Sediment Filters for Commercial RO Systems
- Replacement Carbon Filters for Commercial RO Systems
- Replacement Filter Housings for Commercial RO Systems
- Replacement Components for Commercial RO Systems
- Membrane Cleaning Cartridges for Commercial RO Systems
Contact us
for a quote or for any additional information
or call us at 1.800.321.9321