Series P: 350 to 1,000 GPD Reverse Osmosis Systems
      
        - 10” Big Blue Carbon Block and 5 Micron Sediment Filter
 
        - 2.5” Diameter × 21” Length Thin Film Reverse Osmosis Membranes in SS Housings
 
        - RO System Dimensions: 21.75”L × 20”W × 33”H
 
       
     | 
    
    
      
         
      
     | 
  
| 
 Model No.* 
 | 
 RO System Capacity 
 | 
 RO Membrane Qty. 
 | 
 Connections 
 | 
 Approx. Shipping Weight (Lb/Kg) 
 | 
| 
 GPD 
 | 
 m³/day 
 | 
 Inlet 
 | 
 Conc. 
 | 
 Perm. 
 | 
| 
 P-125A 
 | 
 350 
 | 
 1.3 
 | 
 1 
 | 
 ⅜” 
 | 
 ⅜” 
 | 
 ¼” 
 | 
 60 
 | 
| 
 P-225A 
 | 
 700 
 | 
 2.7 
 | 
 2 
 | 
 ⅜” 
 | 
 ⅜” 
 | 
 ¼” 
 | 
 65 
 | 
| 
 P-325A 
 | 
 1,000 
 | 
 3.8 
 | 
 3 
 | 
 ⅜” 
 | 
 ⅜” 
 | 
 ¼” 
 | 
 70 
 | 
 
  
    
    
      Series T: 600 to 1,700 GPD Reverse Osmosis Systems
      
        - 20” Big Blue Carbon Block and 5 Micron Sediment Filter
 
        - 2.5” Diameter × 40” Length Thin Film Reverse Osmosis Membranes in SS Housings
 
        - RO System Dimensions: 23”L × 24”W × 55”H
 
       
     | 
    
    
      
         
      
     | 
  
| 
 Model No.* 
 | 
 RO System Capacity 
 | 
 RO Membrane Qty. 
 | 
 Connections 
 | 
 Approx. Shipping Weight (Lb/Kg) 
 | 
| 
 GPD 
 | 
 m³/day 
 | 
 Inlet 
 | 
 Conc. 
 | 
 Perm. 
 | 
| 
 T-125A 
 | 
 600 
 | 
 2.0 
 | 
 1 
 | 
 ¾” 
 | 
 ½” 
 | 
 ½” 
 | 
 95 
 | 
| 
 T-225A 
 | 
 1,200 
 | 
 4.5 
 | 
 2 
 | 
 ¾” 
 | 
 ½” 
 | 
 ½” 
 | 
 105 
 | 
| 
 T-325A 
 | 
 1,700 
 | 
 6.4 
 | 
 3 
 | 
 ¾” 
 | 
 ½” 
 | 
 ½” 
 | 
 115 
 | 
 
  
    
    
      Series M: 2,000 to 10,000 GPD Reverse Osmosis Systems
      
        - 20” Big Blue Carbon Block Filters (2) and 5 Micron Sediment Filter
 
        - 4” Diameter × 40” Length Thin Film Reverse Osmosis Membranes in SS Housings
 
        - RO System Dimensions: 35”L × 24”W × 55”H
 
       
     | 
    
    
      
         
      
     | 
  
| 
 Model No.* 
 | 
 RO System Capacity 
 | 
 RO Membrane Qty. 
 | 
 Connections 
 | 
 Approx. Shipping Weight (Lb/Kg) 
 | 
| 
 GPD 
 | 
 m³/day 
 | 
 Inlet 
 | 
 Conc. 
 | 
 Perm. 
 | 
| 
 M-14A 
 | 
 2,000 
 | 
 7.5 
 | 
 1 
 | 
 ¾” 
 | 
 ½” 
 | 
 ½” 
 | 
 220 
 | 
| 
 M-24A 
 | 
 4,000 
 | 
 15.0 
 | 
 2 
 | 
 ¾” 
 | 
 ½” 
 | 
 ½” 
 | 
 235 
 | 
| 
 M-34A 
 | 
 5,800 
 | 
 22.0 
 | 
 3 
 | 
 ¾” 
 | 
 ½” 
 | 
 ½” 
 | 
 250 
 | 
| 
 M-44A** 
 | 
 7,500 
 | 
 28.0 
 | 
 4 
 | 
 ¾” 
 | 
 ½” 
 | 
 ½” 
 | 
 265 
 | 
| 
 M-54A** 
 | 
 9,000 
 | 
 34.0 
 | 
 5 
 | 
 ¾” 
 | 
 ½” 
 | 
 ½” 
 | 
 280 
 | 
| 
 M-64A** 
 | 
 10,000 
 | 
 38.0 
 | 
 6 
 | 
 ¾” 
 | 
 ½” 
 | 
 ½” 
 | 
 295 
 | 
 
Voltage Code and RO System Notes
- *Voltage: Please add our voltage codes to the end of the model number when ordering. Example: M-14A-116
Voltage Codes:
 • 116= 110v, 1ph, 60hz 
 • 216= 220/230v, 1ph, 60hz 
 • 215 = 220/230v, 1ph, 50hz
**M-44A, M-54A, and M-64A are available in 215 and 216 voltage only.   116 is not available for these models.  
- Recommended Pre-Treatment Equipment:  All pretreatment equipment and SDI test kits are available from Applied Membranes.
 Water Softener: Hardness must be removed if present in feed water prior to RO system to avoid scaling the membranes. 
Multimedia filter: If feed water exceeds <1 NTU turbidity, or silt density index (SDI) of 3, media filter pretreatment recommended. 
- Systems rated at: 77°F (25°C) using 1000 ppm sodium chloride solution operating at approx. 200 psi.
 
- Capacity Basis: 24 hrs/day
 
- Minimum feed pressure to RO System: 40-60 PSI. 
 RO System capacity changes significantly with water temperature 
- All dimensions and weights are approximate.
 
     
     
    
    
      Key Features:
- Over 40 years of experience is reflected in our quality
 
- Compact, Heavy Duty, Powder Coated Frame
 
- Proven components used throughout the system
 
- Conservatively engineered for reliable long term performance
 
- Factory tested to ensure trouble-free operation
 
Why Applied Membranes?
- Over 10,000 commercial/industrial systems in operation
 
- Our products are being used in over 100 countries worldwide
 
- From packaged systems to custom engineered Reverse Osmosis systems, we can take care of your needs
 
- We are one of the few companies that have the expertise to provide Reverse Osmosis systems for drinking water, boiler feed water, seawater, desalination, ultrapure water, USP water, and water reuse.
 
- We have supplied more systems to more countries than most of our competitors
 
- Our customers include major national and international companies in every field of application
 
- We stock more components for all sizes of RO systems than any other company
 
- We have earned an enviable reputation for our product quality, performance reliability and business integrity.
 

      
     
      
     
    
      Standard Features
- Thin Film Composite Membranes in SS Vessels
 
- Big Blue Carbon block and 5M Sediment Prefilters in Housings.
 
- Automatic Inlet Feed Solenoid Valve
 
- System & Recycle Control Valves
 
- Low Pressure Pump Protection
 
- High Pressure RO Pump
 
- (4) Pressure Gauges:  System Pressure, Concentrate Pressure, Filter In and Filter Out.
 
- (3) Panel Mounted Flow Meters: Permeate, Concentrate and Recycle Flow.
 
- Powder Coated Carbon Steel Frame
 
- Boxed and Palletized for Shipment
 
Automatic Microprocessor Controller
Monitors and/or Controls:
- Inlet Valve
 
- Low Pressure Switch
 
- Feed Water Flush at System Shut-Down
 
- Pre-Treatment Backwash/Lockout
 
- System On/Off According to Tank Level 
(Floats Purchased Separately) 
- Low Pressure Shutdown/Auto Restart
 
- Power On/ Pretreatment Lockout
 
- Storage Tank Full/System Flush
 
     
       
    
    
      
- Spot Free Rinse/Car Wash
 
- Water Stores
 
- Whole House
 
- Hotels
 
- Breweries
 
- Restaurants
 
- Laboratories
 
- Large Office
 
 
 | 
- Institutions
 
- Ice Makers
 
- Humidification
 
- Misting
 
- Commercial
 
- Manufacturing
 
- Rinse Water 
 
- And a wide variety of other applications
 
 
 | 
     
      
    
     
      Replacement Parts & Consumables for Advantage Series Reverse Osmosis Systems