Los sistemas de ósmosis inversa de la serie Advantage de AMI están diseñados para producir agua con bajo contenido de sólidos disueltos a partir de agua del grifo o de pozo. Estos sistemas utilizan membranas de alta eficiencia y bajo consumo energético, y funcionan con alta recuperación, lo que ofrece bajos costos de mantenimiento y operación. Incorporan filtros de carbón para la eliminación del cloro y prefiltración de sedimentos antes de la ósmosis inversa, lo que resulta en una unidad compacta lista para funcionar.
- Compacto, personalizable y ampliable
- Bajo mantenimiento y bajos costos operativos
- Completamente ensamblado y listo para funcionar
Model No.* |
RO System Capacity |
RO Membrane Qty. |
Connections |
Approx. Shipping Weight (Lb/Kg) |
|||
GPD |
m³/day |
Inlet |
Conc. |
Perm. |
|||
P-125A |
350 |
1.3 |
1 |
⅜” |
⅜” |
¼” |
60 |
P-225A |
700 |
2.7 |
2 |
⅜” |
⅜” |
¼” |
65 |
P-325A |
1,000 |
3.8 |
3 |
⅜” |
⅜” |
¼” |
70 |
Model No.* |
RO System Capacity |
RO Membrane Qty. |
Connections |
Approx. Shipping Weight (Lb/Kg) |
|||
GPD |
m³/day |
Inlet |
Conc. |
Perm. |
|||
T-125A |
600 |
2.0 |
1 |
¾” |
½” |
½” |
95 |
T-225A |
1,200 |
4.5 |
2 |
¾” |
½” |
½” |
105 |
T-325A |
1,700 |
6.4 |
3 |
¾” |
½” |
½” |
115 |
Model No.* |
RO System Capacity |
RO Membrane Qty. |
Connections |
Approx. Shipping Weight (Lb/Kg) |
|||
GPD |
m³/day |
Inlet |
Conc. |
Perm. |
|||
M-14A |
2,000 |
7.5 |
1 |
¾” |
½” |
½” |
220 |
M-24A |
4,000 |
15.0 |
2 |
¾” |
½” |
½” |
235 |
M-34A |
5,800 |
22.0 |
3 |
¾” |
½” |
½” |
250 |
M-44A** |
7,500 |
28.0 |
4 |
¾” |
½” |
½” |
265 |
M-54A** |
9,000 |
34.0 |
5 |
¾” |
½” |
½” |
280 |
M-64A** |
10,000 |
38.0 |
6 |
¾” |
½” |
½” |
295 |
Voltage Code and RO System Notes
- *Voltage: Please add our voltage codes to the end of the model number when ordering. Example: M-14A-116
Voltage Codes:
• 116= 110v, 1ph, 60hz
• 216= 220/230v, 1ph, 60hz
• 215 = 220/230v, 1ph, 50hz
**M-44A, M-54A, and M-64A are available in 215 and 216 voltage only. 116 is not available for these models.
- Recommended Pre-Treatment Equipment: All pretreatment equipment and SDI test kits are available from Applied Membranes.
Water Softener: Hardness must be removed if present in feed water prior to RO system to avoid scaling the membranes.
Multimedia filter: If feed water exceeds <1 NTU turbidity, or silt density index (SDI) of 3, media filter pretreatment recommended. - Systems rated at: 77°F (25°C) using 1000 ppm sodium chloride solution operating at approx. 200 psi.
- Capacity Basis: 24 hrs/day
- Minimum feed pressure to RO System: 40-60 PSI.
RO System capacity changes significantly with water temperature - All dimensions and weights are approximate.
Key Features:
- Over 40 years of experience is reflected in our quality
- Compact, Heavy Duty, Powder Coated Frame
- Proven components used throughout the system
- Conservatively engineered for reliable long term performance
- Factory tested to ensure trouble-free operation
Why Applied Membranes?
- Over 10,000 commercial/industrial systems in operation
- Our products are being used in over 100 countries worldwide
- From packaged systems to custom engineered Reverse Osmosis systems, we can take care of your needs
- We are one of the few companies that have the expertise to provide Reverse Osmosis systems for drinking water, boiler feed water, seawater, desalination, ultrapure water, USP water, and water reuse.
- We have supplied more systems to more countries than most of our competitors
- Our customers include major national and international companies in every field of application
- We stock more components for all sizes of RO systems than any other company
- We have earned an enviable reputation for our product quality, performance reliability and business integrity.
Características estándar
- Membranas compuestas de película delgada en recipientes de acero inoxidable
- Bloque de carbón Big Blue y prefiltros de sedimentos 5M en carcasas.
- Válvula solenoide de alimentación de entrada automática
- Válvulas de control de sistema y reciclaje
- Protección de bomba de baja presión
- Bomba de ósmosis inversa de alta presión
- (4) Manómetros: Presión del sistema, Presión del concentrado, Filtro de entrada y Filtro de salida.
- (3) Medidores de flujo montados en panel: flujo de permeado, concentrado y reciclado.
- Marco de acero al carbono con recubrimiento en polvo
- Empacado y paletizado para envío
Controlador automático de microprocesador
Monitores y/o Controles :
- Válvula de entrada
- Interruptor de baja presión
- Lavado de agua de alimentación al apagar el sistema
- Pretratamiento de lavado a contracorriente/bloqueo
- Encendido y apagado del sistema según el nivel del tanque
(Flotadores comprados por separado)
Luces indicadoras:
- Apagado por baja presión/reinicio automático
- Bloqueo de encendido/pretratamiento
- Tanque de almacenamiento lleno/Lavado del sistema
|
|
Repuestos y consumibles para sistemas de ósmosis inversa de la serie Advantage
- Folleto de especificaciones del sistema de ósmosis inversa compacto de la serie Advantage
- Folleto de marketing del sistema de ósmosis inversa compacto de la serie Advantage
- Catálogo de sistemas de tratamiento de agua por membrana AMI
- ¿Qué es la ósmosis inversa? (Sobre la ósmosis inversa - Artículo técnico)
Ordenar por