Indicadores de temperatura AshCroft
Los indicadores de temperatura Ashcroft Serie EI cuentan con un sello hermético y un ajuste externo en la parte trasera de la caja. Los termómetros bimetálicos industriales Ashcroft® incorporan un dial Maxivision® que elimina el paralaje al colocar la aguja en el mismo plano que las graduaciones. El sello hermético impide la entrada de humedad en la caja, minimizando así la posibilidad de formación de hielo o empañamiento en su interior. La ventana permanece transparente y, con el dial Maxivision®, se garantizan lecturas precisas.
Disponible en opciones de montaje trasero o inferior.
Información para pedidos del indicador de temperatura Ashcroft serie EI
N.º de modelo |
Descripción |
Rango (°F) |
30EI60L0250 | Medidor de temperatura Ashcroft – Montaje inferior | 0-250 °F |
30EI60R0250 | Medidor de temperatura Ashcroft (montaje posterior) | 0-250 °F |
Benefits of Ashcroft EI Series Temperature Indicators
- 1% full span accuracy ASME B40.200 (ASMEB40.3 Grade A)
- Maximum ambient temp. is 200°F (94°C)
- Hermetically sealed case to prevent entry of moisture, interior corrosion and coil freeze-up.
- External adjustment permits zero reset from outside the case.
- Maxivison® dial allows readability from any angle without parallax error.
- Silicone coil dampening (up to 400°F) provides vibration dampening and improves response time.
- All-welded stainless steel construction
- Heavy-Duty glass lens
- Protection IP 65
- Five year limited warranty
Ashcroft EI Series Temperature Indicator Features
- Each instrument is manufactured to a standard accuracy of 1% of span (ASME B40.3, Grade A) traceable to the National Institute of Standards and Technology (NIST).
- The bimetal coils are heat treated for stability and overtemperature capability.
- A single helix is used to reduce lag time.
- The bearings are made of a low-friction long-life material.
- The shafts are made of specially drawn stainless steel with a very smooth finish.
- All joints are welded, and the weld between the stem and the outlet is located at the bottom of the threads to eliminate the possibility of crevice corrosion.
- Silicone dampening is included for improved vibration resistance.
Aplicaciones de los indicadores de temperatura de la serie EI de Ashcroft
- Tratamiento de agua
- Sistemas de ósmosis inversa
- Agua del grifo
- Agua subterránea
- Ósmosis inversa de agua de mar
- Tratamiento de agua comercial
Productos de instrumentación de ósmosis inversa comerciales relacionados
Literatura del fabricante y AMI para los indicadores de temperatura de la serie EI de Ashcroft
Ordenar por