Series P: 350 to 1,000 GPD Reverse Osmosis Systems
- 10” Big Blue Carbon Block and 5 Micron Sediment Filter
- 2.5” Diameter × 21” Length Thin Film Reverse Osmosis Membranes in SS Housings
- RO System Dimensions: 21.75”L × 20”W × 33”H
|
|
Model No.*
|
RO System Capacity
|
RO Membrane Qty.
|
Connections
|
Approx. Shipping Weight (Lb/Kg)
|
GPD
|
m³/day
|
Inlet
|
Conc.
|
Perm.
|
P-125A
|
350
|
1.3
|
1
|
⅜”
|
⅜”
|
¼”
|
60
|
P-225A
|
700
|
2.7
|
2
|
⅜”
|
⅜”
|
¼”
|
65
|
P-325A
|
1,000
|
3.8
|
3
|
⅜”
|
⅜”
|
¼”
|
70
|
Series T: 600 to 1,700 GPD Reverse Osmosis Systems
- 20” Big Blue Carbon Block and 5 Micron Sediment Filter
- 2.5” Diameter × 40” Length Thin Film Reverse Osmosis Membranes in SS Housings
- RO System Dimensions: 23”L × 24”W × 55”H
|
|
Model No.*
|
RO System Capacity
|
RO Membrane Qty.
|
Connections
|
Approx. Shipping Weight (Lb/Kg)
|
GPD
|
m³/day
|
Inlet
|
Conc.
|
Perm.
|
T-125A
|
600
|
2.0
|
1
|
¾”
|
½”
|
½”
|
95
|
T-225A
|
1,200
|
4.5
|
2
|
¾”
|
½”
|
½”
|
105
|
T-325A
|
1,700
|
6.4
|
3
|
¾”
|
½”
|
½”
|
115
|
Series M: 2,000 to 10,000 GPD Reverse Osmosis Systems
- 20” Big Blue Carbon Block Filters (2) and 5 Micron Sediment Filter
- 4” Diameter × 40” Length Thin Film Reverse Osmosis Membranes in SS Housings
- RO System Dimensions: 35”L × 24”W × 55”H
|
|
Model No.*
|
RO System Capacity
|
RO Membrane Qty.
|
Connections
|
Approx. Shipping Weight (Lb/Kg)
|
GPD
|
m³/day
|
Inlet
|
Conc.
|
Perm.
|
M-14A
|
2,000
|
7.5
|
1
|
¾”
|
½”
|
½”
|
220
|
M-24A
|
4,000
|
15.0
|
2
|
¾”
|
½”
|
½”
|
235
|
M-34A
|
5,800
|
22.0
|
3
|
¾”
|
½”
|
½”
|
250
|
M-44A**
|
7,500
|
28.0
|
4
|
¾”
|
½”
|
½”
|
265
|
M-54A**
|
9,000
|
34.0
|
5
|
¾”
|
½”
|
½”
|
280
|
M-64A**
|
10,000
|
38.0
|
6
|
¾”
|
½”
|
½”
|
295
|
Voltage Code and RO System Notes
- *Voltage: Please add our voltage codes to the end of the model number when ordering. Example: M-14A-116
Voltage Codes:
• 116= 110v, 1ph, 60hz
• 216= 220/230v, 1ph, 60hz
• 215 = 220/230v, 1ph, 50hz
**M-44A, M-54A, and M-64A are available in 215 and 216 voltage only. 116 is not available for these models.
- Recommended Pre-Treatment Equipment: All pretreatment equipment and SDI test kits are available from Applied Membranes.
Water Softener: Hardness must be removed if present in feed water prior to RO system to avoid scaling the membranes.
Multimedia filter: If feed water exceeds <1 NTU turbidity, or silt density index (SDI) of 3, media filter pretreatment recommended.
- Systems rated at: 77°F (25°C) using 1000 ppm sodium chloride solution operating at approx. 200 psi.
- Capacity Basis: 24 hrs/day
- Minimum feed pressure to RO System: 40-60 PSI.
RO System capacity changes significantly with water temperature
- All dimensions and weights are approximate.
Key Features:
- Over 40 years of experience is reflected in our quality
- Compact, Heavy Duty, Powder Coated Frame
- Proven components used throughout the system
- Conservatively engineered for reliable long term performance
- Factory tested to ensure trouble-free operation
Why Applied Membranes?
- Over 10,000 commercial/industrial systems in operation
- Our products are being used in over 100 countries worldwide
- From packaged systems to custom engineered Reverse Osmosis systems, we can take care of your needs
- We are one of the few companies that have the expertise to provide Reverse Osmosis systems for drinking water, boiler feed water, seawater, desalination, ultrapure water, USP water, and water reuse.
- We have supplied more systems to more countries than most of our competitors
- Our customers include major national and international companies in every field of application
- We stock more components for all sizes of RO systems than any other company
- We have earned an enviable reputation for our product quality, performance reliability and business integrity.

Standard Features
- Thin Film Composite Membranes in SS Vessels
- Big Blue Carbon block and 5M Sediment Prefilters in Housings.
- Automatic Inlet Feed Solenoid Valve
- System & Recycle Control Valves
- Low Pressure Pump Protection
- High Pressure RO Pump
- (4) Pressure Gauges: System Pressure, Concentrate Pressure, Filter In and Filter Out.
- (3) Panel Mounted Flow Meters: Permeate, Concentrate and Recycle Flow.
- Powder Coated Carbon Steel Frame
- Boxed and Palletized for Shipment
Automatic Microprocessor Controller
Monitors and/or Controls:
- Inlet Valve
- Low Pressure Switch
- Feed Water Flush at System Shut-Down
- Pre-Treatment Backwash/Lockout
- System On/Off According to Tank Level
(Floats Purchased Separately)
- Low Pressure Shutdown/Auto Restart
- Power On/ Pretreatment Lockout
- Storage Tank Full/System Flush
- Spot Free Rinse/Car Wash
- Water Stores
- Whole House
- Hotels
- Breweries
- Restaurants
- Laboratories
- Large Office
|
- Institutions
- Ice Makers
- Humidification
- Misting
- Commercial
- Manufacturing
- Rinse Water
- And a wide variety of other applications
|
Replacement Parts & Consumables for Advantage Series Reverse Osmosis Systems