跳至内容

AMI Aurora系列


Applied Membranes, Inc. Aurora系列紫外线水处理系统
NSF 认证

Applied Membranes Aurora 系列经 NSF 验证的紫外线水处理系统经过 NSF International 测试和认证,符合 CSA B483.1 和 NSF/ANSI 55 的消毒性能、 A 级主要消毒或B 级补充消毒标准。

应用膜 Solapur Aurora 系列配备紫外线强度监测器,可持续监测消毒和水质安全。先进的可扩展控制器配备保护式灯泡更换功能,可扩展性无限,并配备全彩显示屏,可显示紫外线强度、诊断信息和警告信息。

Class A for primary disinfectionClass B for supplemental disinfection

NSF A Validated UV Systems - Solapur Aurora UV Specifications and Ordering Information

NSF Certified UV Systems NSF Validated Ultraviolet systems for Water Disinfection TreatmentSystems Tested and Certified by NSF International against CSA B483.1 and NSF/ANSI 55 for Disinfection Performance, Class A
Model No.

NSF Class A Flow Rate (@ 40 mJ/cm2 @70% UVT)

In/Out Port

Lamp Watts

Reactor Dimensions
(Dia. x Length)
Lamp Life

UV Monitor

gpm

lpm

Aurora Series NSF-A Class Systems - with Standard Output Lamps
UV-SPNSFA-1.6M 1.6  6.1  1/2" MNPT 8  2.5" x 10.3"
(6.4x26.2cm) 
  9,000 Hours YES
UV-SPNSFA-2.2M 2.2 8.3   1/2" MNPT  15   2.5" x 14.3"
(6.4x36.4cm) 
  9,000 Hours  YES 
UV-SPNSFA-3.4M 3.4 12.9  3/4" MNPT  22   2.5" x 21.3"
(6.4x54.2cm) 
  9,000 Hours  YES 
UV-SPNSFA-6.3M 6.3 23.8  3/4" MNPT  39    2.5" x 35.2"
(6.4x89.5cm)
  9,000 Hours  YES 
UV-SPNSFA-7.9M  7.9 29.9  1" MNPT  50    2.5" x 40"
(6.4x101.6cm)
  9,000 Hours  YES 
Aurora HP Series NSF-A Class Systems - with High Output Lamps
UV-SPNSFA-2.2M-HP  2.2 8.3 1/2" MNPT 18  3.5" x 11.7"
(8.9x29.8cm) 
10,000 Hours YES
UV-SPNSFA-4.0M-HP  4.0 15.1 3/4" MNPT 34  3.5" x 16.5"
(8.9x41.8cm) 
10,000 Hours YES
UV-SPNSFA-5.4M-HP  5.4 20.4 1' MNPT 45  3.5" x 20.0"
(8.9x50.8cm) 
10,000 Hours YES
UV-SPNSFA-7.9M-HP  7.9 29.9 1" MNPT 67  3.5" x 26.9"
(8.9x68.3cm) 
10,000 Hours YES
UV-SPNSFA-18M-HP  18.0 68.1 1-1/2" MNPT 101  3.5" x 40.7"
(8.9x103.4cm) 
10,000 Hours YES

NSF B Validated UV Systems - Solapur Aurora UV Specifications and Ordering Information

NSF Certified UV Systems NSF Validated Ultraviolet systems for Water Disinfection TreatmentSystems Tested and Certified by NSF International against CSA B483.1 and NSF/ANSI 55 for Disinfection Performance, Class B
Model No.

NSF Class B Flow Rate (@ 16 mJ/cm2 @70% UVT)

In/Out Port

Lamp Watts

Reactor Dimensions
(Dia. x Length)
Lamp Life

UV Monitor

gpm

lpm

Aurora Series NSF-B Class Systems - with Standard Output Lamps
UV-SPNSFB-2.9

2.9 11.0 1/2" MNPT 8  2.5" x 10.3"
(6.4x26.2cm)
9,000 Hours NO
UV-SPNSFB-2.9M

YES
UV-SPNSFB-5.2

5.2 19.7 1/2" MNPT 15  2.5" x 14.3"
(6.4x36.4cm) 
9,000 Hours NO
UV-SPNSFB-5.2M

YES
UV-SPNSFB-7.6

7.6 28.8 3/4" MNPT 22  2.5" x 21.3"
(6.4x54.2cm) 
9,000 Hours NO
UV-SPNSFB-7.6M

YES
UV-SPNSFB-13

13 49.2 3/4" MNPT 39   2.5" x 35.2"
(6.4x89.5cm)
9,000 Hours NO
UV-SPNSFB-13M

YES
UV-SPNSFB-22

22 83.3 1" MNPT 50   2.5" x 40"
(6.4x101.6cm)
9,000 Hours NO
UV-SPNSFB-22M

YES
Model No.

NSF Class B Flow Rate (@ 16 mJ/cm2 @70% UVT)

In/Out Port

Lamp Watts

Reactor Dimensions
(Dia. x Length)
Lamp Life

UV Monitor

gpm

lpm

Aurora HP Series NSF-B Class Systems - with High Output Lamps
 UV-SPNSFB-5.4-HP

5.4 20.4 1/2" MNPT 18  3.5" x 11.7"
(8.9x29.8cm) 
10,000 Hours NO
UV-SPNSFB-5.4M-HP

YES
UV-SPNSFB-7.6-HP

7.6 28.8 3/4" MNPT 34  3.5" x 16.5"
(8.9x41.8cm) 
10,000 Hours NO
UV-SPNSFB-7.6M-HP

YES
UV-SPNSFB-13-HP

13 49.2 1" MNPT 45  3.5" x 20.0"
(8.9x50.8cm) 
10,000 Hours NO
UV-SPNSFB-13M-HP

YES
UV-SPNSFB-22-HP

22 83.3 1" MNPT 37  3.5" x 26.9"
(8.9x68.3cm) 
10,000 Hours NO
UV-SPNSFB-22M-HP

YES
UV-SPNSFB-28-HP

28 106 1-1/2" MNPT 101  3.5" x 40.7"
(8.9x103.4cm) 
10,000 Hours NO
UV-SPNSFB-28M-HP

YES

Applied Membranes Ultraviolet Water Treatment Systems for Disinfection of Water

Additional Specifications:

  • Chamber Material:
    • Standard: 304 Stainless Steel, A249 Pressure Rated Tubing, Polished & Passivated
    • HP: 316L Stainless Steel, A249 Pressure Rated Tubing, Polished & Passivated
  • Controller Dimensions:
    • Standard: 6.8" x 3.6" x 3" (17.2 x 9.2 x 10.2 cm)
    • HP: 8.6" x 4.2" x 3.5" (21.7 x 10.8 x 8.9 cm)
  • Maximum Operating Pressure: 150 psi (10 bar)
  • Operating Temperature Range: 36-104°F (2-40°C)
  • Lamp Change Reminder: Audible & Visual - with full-color graphic display showing lamp countdown and diagnostics.
  • Equipped with Lamp-Out Indicator (Audible and Visual)
  • Electrical: 90-265v/60-Hz
  • Models shown above are equipped with USA American Nema 5/15 electric plug. To order in alternative voltages, please add the appropriate voltage code to the end of the part number. (Example: UV-SPNSFA-1.6M-EU)
    • EU: European: CEE 7/7
    • UK: British Standard: BS 1363
    • AU: Australian/New Zealand: AS/NZ 3112

Applied Membranes Ultraviolet Water Treatment Systems are Eco FriendlySolapur Aurora Series NSF Validated Ultraviolet Systems Benefits

  • Tested and Certified by NSF International against CSA B483.1 and NSF/ANSI 55 for Disinfection Performance, Class A or Class B
  • Monitored Systems are Equipped with a UV Intensity Monitor to ensure the proper disinfection and safety of the water
  • User-friendly interface with full-color diagnostics and maintenance reminders
  • A chemical-free way to safeguard your water using no additives
  • No harmful chemical additives - no added taste or odors.
  • Environmentally friendly, cost effective, and energy efficient
  • No disinfection by-products (DBP’s) or residuals
  • No resistance as with chlorine and antibiotics
  • No regrowth of viruses, bacteria and parasites
  • Easy to install and service - simply change the bulb once per year.
  • No moving parts to wear out or break
  • Compact, streamline design takes minimal space.
  • Audible and Visual Lamp Change Reminder and Lamp Fail Alarm to ensure the safety of your water.

Ultraviolet System Advanced Controls Applied Membranes SolapurSolapur Aurora NSF Validated UV System Features

  • Continuous UV monitoring with UV output display (as a %)*
  • System diagnostics and potential fault codes*
  • Color screen controller with protected lamp replacement, includes QR codes, full diagnostics & warnings**
  • Expandability port for future upgrades and options**
  • Visual Sight Port for “Lamp-On” Verification
  • Audible and Visual Lamp Change Reminders and Failure Indicators
  • Sturdy Stainless Steel Reactor Chamber (304 SS for standard models, 316L for HP models)
  • Bayonet-Style Lamp Connector for Easy, No-Tools Change-Out
  • Constant Current Electronic Controller in a Splash-Proof Case
  • Fully Potted Ballast Virtually Eliminates Common Water Damage Issues
  • System is Sold Complete with UV Chamber, Lamp, Sleeve, Controller, Power Supply, Mounting Clamps, and Installation & Maintenance Manual.

 


Helios Aurora Controller Sample Screens

Solapur Helios Plus Ultraviolet System Enhanced Controller Solapur Helios Plus Ultraviolet System Enhanced Controller Solapur Helios Plus Ultraviolet System Enhanced Controller Solapur Helios Plus Ultraviolet System Enhanced Controller
       
Solapur Helios Plus Ultraviolet System Enhanced Controller Solapur Helios Plus Ultraviolet System Enhanced Controller Solapur Helios Plus Ultraviolet System Enhanced Controller Solapur Helios Plus Ultraviolet System Enhanced Controller
       
Solapur Helios Plus Ultraviolet System Enhanced Controller Solapur Helios Plus Ultraviolet System Enhanced Controller Solapur Helios Plus Ultraviolet System Enhanced Controller Solapur Helios Plus Ultraviolet System Enhanced Controller

Solapur Aurora 系列 NSF 验证紫外线系统的常见应用

如果您正在寻找一套经过独立验证的紫外线系统,用于对细菌污染的水源进行初级消毒,Solapur Aurora 系列NSF 55 CLASS A 验证的紫外线系统就是您的解决方案。Solapur NSF A 级验证系统符合 NSF/ANSI 55 对微生物污染水消毒的规定,且符合所有其他公共卫生标准。该系统并非用于将废水或原污水转化为饮用水。该系统旨在安装在视觉上清澈的水面上。NSF/ANSI 55 对废水的定义包括人类和/或动物排泄物、卫生纸以及任何其他旨在存放在用于接收尿液和/或粪便的容器中的材料(黑色废物),以及存放在卫生设备中的其他废物(灰色废物)。如果该系统用于处理未经处理的地表水或受地表水直接影响的地下水,则应在系统上游安装符合相应 NSF/ANSI 标准中囊肿减少要求的装置。

经 NSF 55 B 级验证的紫外线系统是理想的独立验证紫外线系统,可用于对饮用水源进行补充消毒。Solapur NSF B 级系统符合 NSF/ANSI 55 标准,可用于对已消毒的公共饮用水或其他经州或地方卫生机构检测并认定为可供人类饮用的饮用水进行补充杀菌处理。该系统仅用于减少通常存在的非致病性有害微生物。B 级系统不适用于处理受污染的水。

Optional Add-On Modules for NSF Certified UV Water Treatment Systems

Applied Membranes Solapur Helios Ultra UV Systems are fully expandable.  These plug and play modules can be added during installation, or as upgrades at a later date.  Helios Plus and Ultra controllers incorporate an “Infinite Expandability Port” (IEP) which allows for expansion to the UV sensor and all other modules. Each module (including the sensor) comes with both a male and female connection. Connect any device to the controller and all subsequent devices are then connected into the female end of last device added in a “daisy chain” configuration.

Applied Membranes Ultraviolet Water Treatment Systems for Disinfection of Water      

Water Quality Monitor 
compatible with Helios Plus & Ultra systems and allows for remote monitoring of all alarms on the UV system. Three LEDs visually display system functionality from up to 150’ (46m) away.
Applied Membranes Ultraviolet Water Treatment Systems for Disinfection of Water  
Solenoid Module
 will power a remote normally closed solenoid valve (not included). Solenoid will close on lamp failure or when low UV conditions are detected by the sensor. 
Available in 110V. (Part # UV-MOD-SOL1) or 230V (Part # UV-MOD-SOL2)
Applied Membranes Ultraviolet Water Treatment Systems for Disinfection of Water  
TRV (temperature management relief valve)
 allows for a small amount of water to be physically released (dumped) from the UV unit to allow for cooling of the water. Used in applications of extended “no flow” conditions, or when the temperature of the treated water is of a critical nature.  
Applied Membranes Ultraviolet Water Treatment Systems for Disinfection of Water  

4-20mA Module
 will signal transfer to a remote device such as a data logger or computer. 
Part #: UV-MOD-420. 
Applied Membranes Ultraviolet Water Treatment Systems for Disinfection of Water  

Remote Alarm (Dry Contact) Module
 to signal transfer to a remote alarm or dry contacts. 
Part #:  UV-MOD-RAM

Replacement Lamps & Quartz Sleeve for Solapur Helios Series UV Systems

UV System Model
NSF A & NSF B

Replacement Lamp

Replacement Quartz Sleeve

UV-SPNSFA-1.6M
UV-SPNSFB-2.9
UV-SPNSFB-2.9M

UV-SPH-2-L UV-SPH-2SLV
UV-SPNSFA-2.2M
UV-SPNSFB-5.2
UV-SPNSFB-5.2M
UV-SPH-3-L UV-SPH-3SLV
UV-SPNSFA-3.4M
UV-SPNSFB-7.6
UV-SPNSFB-7.6M
UV-SPH-6-L UV-SPH-6SLV
UV-SPNSFA-6.3M
UV-SPNSFB-13
UV-SPNSFB-13M
UV-SPH-11-L UV-SPH-11SLV
UV-SPNSFA-7.9M
UV-SPNSFB-22
UV-SPNSFB-22M
UV-SPH-15-L UV-SPH-15SLV
UV-SPNSFA-2.2M-HP
UV-NSFB-5.4-HP
UV-NSFB-5.4M-HP
UV-SPH-5-HPL  UV-SPH-5SLV
UV-SPNSFA-4.0M-HP
UV-NSFB-7.6-HP
UV-NSFB-7.6M-HP
UV-SPH-10-HPL UV-SPH-10SLV
UV-SPNSFA-5.4M-HP
UV-NSFB-13-HP
UV-NSFB-13M-HP
UV-SPH-15-HPL UV-SPH-15SLV 
UV-SPNSFA-7.9M-HP
UV-NSFB-22-HP
UV-NSFB-22M-HP
UV-SPH-25-HPL UV-SPH-25SLV 
UV-SPNSFA-18M-HP
UV-NSFB-28-HP
UV-NSFB-28M-HP
UV-SPH-40-HPL  UV-SPH-40SLV
Solapur Helios Ultraviolet Systems UV Lamp and Sleeve

Replacement Controllers & Power Supplies for Solapur Aurora NSF Certified UV Systems

Controlller Model

Voltage

Controllers for Aurora Series Standard Systems - Class A & Class B   
UV-CHP-US North American NEMA 5-15 (110V./50-60Hz)
UV-CHP-EU European CEE 7/7 (230V./50-60Hz)
UV-CHP-UK British BS 1363 (230V./50-60Hz)
UV-CHP-AU Australian AS/NZS 3112 (230V./50-60Hz)
Controller for Aurora HP Series NSF Validated Systems (With High Output Lamps)
UV-CH-HP All voltages (power cord sold separately) 

Controller for NSF Validated UV System