K系列商用和工业RO系统
这些工业级 RO 系统旨在从自来水或井水中生产低溶解固体水,使用高效反渗透膜实现可靠的长期性能。
应用包括半导体制造、锅炉给水、药品生产、市政水处理、中水回用、食品和饮料加工、装瓶厂等。
AMI K系列RO系统采用久经考验的可靠组件,并安装在坚固的粉末涂层钢框架上。多年的设计经验确保了其易于维护和性能优化。
K系列系统采用直径8英寸、长度40英寸的RO膜元件。压力容器水平安装,每个容器包含多个膜元件,以实现高容量处理量。

Series K Commercial Industrial RO Systems Ordering Information
Model No. |
RO System Capacity |
Membrane Elements |
Line Sizes |
System Dimensions |
Approx. Shipping Weight |
||||||
GPM |
GPD |
m³/hr |
Inlet |
Perm. |
Conc. |
Length |
Depth |
Height |
|||
K-48B |
20 |
28,800 |
4.5 |
4 |
2 |
1½ |
1½ |
120/305 |
44/112 |
75/191 |
1,310/594 |
K-68C |
30 |
43,200 |
7 |
6 |
2 |
1½ |
1½ |
154/391 |
44/112 |
75/191 |
1,425/646 |
K-98C |
40 |
57,600 |
9 |
9 |
2 |
1½ |
1½ |
154/391 |
44/112 |
75/191 |
1,735/787 |
K-128D |
55 |
79,200 |
13 |
12 |
3 |
2 |
2 |
194/493 |
60/152 |
76/193 |
2,005/909 |
K-168D |
75 |
108,000 |
17 |
16 |
3 |
2 |
2 |
194/493 |
60/152 |
76/193 |
2,275/1,032 |
K-208D |
95 |
136,800 |
22 |
20 |
3 |
3 |
2 |
194/493 |
60/152 |
76/193 |
2,645/1,200 |
K-248D |
115 |
165,600 |
26 |
24 |
4 |
3 |
2 |
194/493 |
60/152 |
76/193 |
2,910/1,320 |
K-288D |
135 |
194,400 |
31 |
28 |
4 |
3 |
2 |
194/493 |
60/152 |
76/193 |
3,280/1,488 |
K-368F |
175 |
252,000 |
40 |
36 |
4 |
3 |
2 |
288/731 |
60/152 |
76/193 |
3,795/1,721 |
K-428F |
200 |
288,000 |
45 |
42 |
4 |
3 |
2 |
288/731 |
60/152 |
76/193 |
5,275/2,392 |
K-488F |
225 |
324,000 |
51 |
48 |
4 |
3 |
2 |
288/731 |
60/152 |
76/193 |
5,660/2,567 |
K-548F |
250 |
360,000 |
57 |
54 |
6 |
4 |
3 |
custom |
custom |
custom |
7,140/3,245 |
K-608F |
275 |
396,000 |
63 |
60 |
6 |
4 |
3 |
custom |
custom |
custom |
8,680/3,945 |
K-668F |
300 |
432,000 |
68 |
66 |
6 |
4 |
3 |
custom |
custom |
custom |
10,285/4,675 |
K-728F |
325 |
460,000 |
74 |
72 |
6 |
4 |
3 |
custom |
custom |
custom |
11,890/5,404 |
Note: Skid dimensions do not include CIP.
Notes and Voltage/ Ordering Information
- Systems rated at 77°F (25°C) using 2000 ppm feed water and approx. 225 psi (16 kg/cm²) pressure. System capacity changes significantly with water temperature and feed TDS. For higher TDS, a water analysis must be supplied and could result in modifications to the system.
- Chlorine must be removed with a carbon filter or with chemical injection prior to the RO System, if present in the feed water.
- Water must be pretreated by softener or antiscalant to avoid scaling the membranes.
All dimensions and weights are approximate.
Please add our voltage codes to the end of the model number when ordering:
Example: J-84B-236 = 220/230v/3 ph/60 Hz
Voltage Codes Single Phase Not Available |
|
|
|
Standard Equipment
|
|
Microprocessor Controller for Automatic Operation (Standard)
Optional Equipment
|
PLC Controller |
|
选装设备 |
||
|
|
替换零件和耗材 |
排序方式