Complete Seawater Reverse Osmosis Systems

Series S Seawater RO - 2,000 - 100,000 Gallons per Day


Designed to convert seawater to drinking water, these seawater desalination systems use high quality reverse osmosis seawater membranes in the water purification process. The product water is used in a variety of areas including hotels, resorts, navy, and off-shore platforms. Designed for the demanding requirements of the marine environment, these seawater systems use our proven technology to give reliable performance.

Key Features:

  • Over 25 years of experience is reflected in our quality

  • Heavy duty powder coated frame

  • Proven components are used throughout the RO system

  • Microprocessor Controlled Operation

  • Conservatively engineered for reliable long term performance

  • Factory tested to ensure trouble-free operation

Click Here to Request a Quote for a Seawater Reverse Osmosis System

Seawater Reverse Osmosis RO System Seawater Desalination Water System
Click a photo to view the full-size image.

STANDARD EQUIPMENT- Series S Seawater RO Systems

  • Thin Film Composite Seawater Membranes

  • FRP Seawater Pressure Vessels

  • Prefilter & Housing

  • 316 Stainless Steel Pressure Gauges

  • 316 Stainless Steel Low and High Pressure Switches

  • 316 Stainless Steel Back Pressure Regulator

  • Low and High Pressure Safeguards

  • Stainless Steel High Pressure Pumps

  • Pulsation Dampner

  • Pressure Relief Valve

  • Antiscalant Injection

  • Auto Permeate Flush System with Tank, Pump & Controls

  • Cleaning Ports

  • Auto Operation with Level Controls

  • Reset Switch to Restart

  • Powder Coated Skid

  • Permeate and Concentrate Flowmeters

  • Microprocessor Controller. Operating conditions are displayed on an LCD Display with:
    – Delayed Start-Up of High Pressure Pump
    – Low and High Pressure Switch
    – RO and Auxiliary Pump Control Relays
    – Product Water Quality TDS
    – Permeate Dump
    – Membrane Permeate Flush at Each Shut-down
    – RO Storage Tank Full and Low
    – Pretreatment Lock Out

 

OPTIONAL EQUIPMENT-  Seawater Reverse Osmosis Systems

  • Ultraviolet Sterilizer*
  • Sodium Bisulfite or Chlorine Injection System*
  • Differential Pressure Gauge
  • Energy Recovery
  • Turbidity Meter
  • ORP Meter
  • Duplex Stainless Steel High Pressure Pump
  • Multimedia Filters
  • Crating*

* Recommended Minimum Options

 

Series S Seawater RO System Specifications

Click Here to Request a Quote for a Seawater Reverse Osmosis System

Model Capacity Number of elements* Element Dia. Line sizes Dimensions Approx. Weight
GPM GPD m3/day Inlet Perm Conc Length Width Height
in. cm. lb kg
in. cm. in. cm. in. cm. in. cm. in. cm. in. cm.
S-24A 1.5 2,000 6 2 4 10 0.75 2 0.75 2 0.75 2 100 254 36 92 72 183 1200 545
S-34A 2 3,000 11 3 4 10 0.75 2 0.75 2 0.75 2 100 254 36 92 72 183 1285 585
S-44A 3 4,000 15 4 4 10 1.5 3.8 0.75 2 1.5 3.8 100 254 36 92 72 183 1375 625
S-64B 4 6,000 23 6 4 10 1.5 3.8 0.75 2 1.5 3.8 134 340 36 92 72 183 1685 765
S-28B 7 10,000 40 2 8 20 1.5 3.8 0.75 2 1.5 3.8 134 340 44 112 72 183 1805 820
S-38A 10 15,000 60 3 8 20 2 5.1 0.75 2 2 5.1 134 340 44 112 72 183 3550 1610
S-48B 14 20,000 75 4 8 20 2 5.1 1.0 2.5 2 5.1 134 340 44 112 72 183 3790 1720
S-68B 17 25,000 95 6 8 20 2 5.1 1.5 3.8 2 5.1 134 340 44 112 72 183 4070 1845
S-98C 24 35,000 130 9 8 20 3 7.6 1.5 3.8 3 7.6 174 442 44 112 72 183 5760 2651
S-128F 35 50,000 190 12 8 20 3 7.6 2.0 5.1 3 7.6 300 762 44 112 72 183 7330 3325
S-188F 52 75,000 284 18 8 20 6 15.2 2.5 6.4 6 15.2 300 762 44 112 72 183 9475 1575
S-248F 70 100,000 380 24 8 20 6 15.2 2.5 6.4 6 15.2 300 762 44 112 72 183 12010 5445
S-308F 92 132,000 500 30 8 20 6 15.2 3 7.6 6 15.2 300 762 44 112 72 183 13950 6330

* Elements are 40" (102 cm) in length

 

NOTES- Series S RO Systems
  • All dimensions and weights are approximate.
  • Based on 35,000 ppm seawater at 77°F (25°C). Recovery in the range of 10-40% depending on the system size.
  • Operating pressure 800-1000 psi (57-71 kg/cmē).

 

ORDERING INFORMATION- Series S RO Systems
Please add our voltage codes to the end of the model number when ordering.  Example:  S-24A-236 = 220/230v / 3 ph / 60 hz
voltage codes: 236 = 220 or 230v/ 3ph/ 60 hz
436 = 460 or 480v/ 3ph/ 60 hz
235 = 220v/3ph/50hz
335 = 380v/3ph/50 hz
No Single Phase Available
Replacement Parts & Consumables for Series S Reverse Osmosis Systems

This page was last updated 01/22/09


 

For prompt, courteous and reliable service, contact us today!


Home Products Catalog How To Order Company Info Contact Us Download Forms Technical Site Search Overstock Sale Employment Order Online
Back Up Next
Series SY Systems Series S Systems Custom Seawater RO Systems

Copyright Đ 2010 Applied Membranes, Inc. All Rights Reserved.

 

 

[Contact Us] [How to Purchase our Products] [Download Catalog] [Download Manuals] [Download Forms & Product Literature] [Track an Order] [Membranes] [RO Systems] [Seawater Desalination Systems] [Water Treatment Systems] [Media Filtration] [Water Softeners] [Iron Filters] [Filters & Housings] [Membrane Housings/Pressure Vessels] [Residential Components] [Pumps] [Membrane Chemicals] [Ultraviolet] [Water Quality Test Equipment] [About Applied Membranes]